摘要
为了验证不同的检测方法(穿孔萃取法和干燥器法)对人造板甲醛释放量检测结果的影响,试验选取甲醛释放量不同的两种密度板进行检测。结果显示,两种试验方法测量的甲醛释放量对应的技术指标值,其检测结论在一定范围内是一致的,超出此范围可能会得出不同的结论。
In order to verify effects on MDF formaldehyde emission by different test methods(perforator and dryer),two density MDF that contain different amount of formaldehyde are selected in this experiment. The results shows that conclusions of formaldehyde amount by two test methods are almost the same. If the index value surpasses the scope,the conclusions may be different.
出处
《工程质量》
2015年第3期40-42,共3页
Construction Quality
基金
中国建筑科学研究院青年基金项目(2011011233103003)
关键词
密度板
甲醛释放量
穿孔萃取法
干燥器法
MDF
formaldehyde emission
extraction method
desiccator method