摘要 目的 :探讨红外耳温计在高龄老年患者中的应用情况、优缺点及使用过程中的注意事项。方法 :随机选择2013年10月医院干部病房84例年龄>65岁的住院患者分别进行耳温(左耳和右耳)及腋温的测量,将所测得的数值利用SPSS13.0统计学软件进行测量结果的分析、比较。结果 :同时、同一患者水银体温计测得的耳温均高于腋温0.27℃,两者差异具有统计学意义(P<0.01);左、右耳温差异无统计学意义(P>0.05)。结论:红外耳温计具有快速、安全、使用简单方便等优点,且测温准确稳定,更适合高龄老年患者体温的测量,值得临床推广应用。 Objective To investigate the application, advantages, disadvantages and precautions of infrared ear thermometer for elderly patients. Methods Totally 84 patients older than 65 years old hospitalized in October 2013 were selected randomly, and underwent temperature measurement at left ear, right ear and axilla. Then obtained values were analyzed and compared with SPSS13.0 statistics software. Results For the same patient, the ear temperature was always higher than axillary temperature by 0.27 ℃ and the difference was significant with P0.01, while there was no statistical significance for the difference between the two ears temperature with P 0.05. Conclusion Infrared ear thermometer can measure the body temperature of the elderly patient rapidly, safely and accurately, and thus is worth popularizing clinically.
出处 《医疗卫生装备》 CAS 2015年第2期81-83,92,共4页 Chinese Medical Equipment Journal
关键词 高龄老年患者 红外耳温计 腋温 对比研究 elderly patient infrared ear thermometer axillary temperature comparative study
  • 相关文献

参考文献11

二级参考文献51

共引文献58

同被引文献71

  • 1陈蓉.红外耳温计应用于痴呆患者的临床观察[J].人民军医,2011,54(S1):30-31. 被引量:2
  • 2柏成玉,原遵东,王铁军.红外耳温计的校准[J].计量技术,2007(4):46-49. 被引量:9
  • 3余海苏,王桂芬.饮用温开水对腋温的影响[J].护理学杂志(外科版),2007,22(5):29-30. 被引量:8
  • 4李小寒,尚少梅.基础护理学[M].5版.北京:人民卫生出版社,2013:6-20.
  • 5American Society for Testing and Materials. E1965-98, Standard specification for infrared thermometers for inter- mittent determination of patient temperature [S]. West Conshohocken: ASTM, 2003.
  • 6European Committee for Standardization. EN 12470-5: 2003(E) ,Clinical thermometers. Performance of infra-red ear thermometers (with maximum device)[S~. Brussels: CEN,2003.
  • 7Japanese Standards Association. JIS T-4207, Infrared ear thermometersES~. Tokyo: JSA, 2005.
  • 8Tsai S. Comparison measurements of infrared ear ther- mometers against three types of blackbody sources[J]. Int J Thermophys, 2010,31 : 1821-1831.
  • 9ZHU Ying-song. - 50 to 4- i50 ~C heat pipe blackbody source for radiation thermometer calibrationr-A~. Proc. of Temperature; its measurement and control in science and industry[C]. 1982,559-565.
  • 10Hollandt J, Friedrich R, Gutschwager B, et al. High-accu- racy radiation thermometry at the national metrology in- stitute of germany, the PTB[J]. High Temperatures-High Pressures, 2003/2004,35/36 : 379-415.

引证文献7

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部