观察机械通气患者呼吸机管路细菌污染以及对呼吸机相关性肺炎的影响 被引量:26

Bacterial contamination of ventilator circuit and its influence on ventilator associated pneumonia in mechanically ventilated patients
下载PDF
导出
摘要 目的:观察重症监护病房( ICU)内机械通气患者呼吸机管路细菌污染状态以及呼吸机管路更换对呼吸机相关性肺炎( VAP)发生率的影响,为合理进行呼吸机管路管理提供依据。方法将ICU内161例机械通气患者根据换管时间分组,其中81例患者每天分别进行呼吸机管路不同部位细菌培养、痰培养,比较细菌生长率的情况;对不同组间VAP的发生率及预后进行比较。结果呼吸机管路细菌以革兰阴性菌为主,管路与人工气道接口处细菌生长率(84.65%)最高(P<0.01),进气管路细菌培养与痰培养一致率(41.49%)较低(P<0.01);呼吸机进气管路、出气管路、与人工气道接口处细菌生长均与时间呈正相关,相关系数( r)分别为0.9694、0.9082、0.6384。细菌生长的时间先后顺序依次为人工气道接口处、出气管路、进气管路。不同换管时间患者VAP的发生率及预后比较差异无统计学意义(P>0.05)。结论机械通气患者呼吸机管路细菌污染率高,但调整更换呼吸机管路的更换周期对VAP的发生率无影响。 Objective To survey the status of ventilator circuit with bacterial contamination and the influence on morbidity of VAP associated with ventilator circuit changes in mechanically ventilated patients.Methods According to the frequency of ventilator circuit changes, 161 patients with mechanical ventilation in ICU were divided into different groups.Bacterial culture of different locations in ventilator circuit and sputum culture were made every day in 81 patients in order to compare the rate of bacterial growth, the difference of morbidity of VAP and prognosis.Results Gram-negative bacteria is superior in ventilator circuit.Statistically, the rate of bacterial growth ( 84.65%) was the highest in circuit and artificial airway joints(P〈0.01).The consistent rate of bacterial culture of inspiratory tube and sputum culture(41.49%)was low(P〈0.01).The rates of bacterial growth in inspiratory tube, exspiratory tube and artificial airway joints are positively correlated with time ( r =0.9694, 0.9082, 0.6384) .The time sequence of bacteria growth were at the artificial airway joints, inspiratory tube and exspiratory tube.There were no statistical differences in the morbidity of VAP and prognosis among in the groups which were divided by frequency of ventilator circuit changes( P〉0.05) .Conclusion The rate of ventilator circuit with bacterial contamination in mechanically ventilated patients is high, but it has no effect on the morbidity of VAP by adjusting the frequency of ventilator circuit changes.
出处 《中国急救医学》 CAS CSCD 北大核心 2015年第3期267-270,共4页 Chinese Journal of Critical Care Medicine
基金 卫生部国家临床重点专科建设项目(2011-873) 天津市医药卫生科技攻关课题(2010KG103)
关键词 重症监护病房(ICU) 呼吸机相关性肺炎(VAP) 细菌 呼吸机管路管理 ICU Bacteria Management of ventilator circuit
  • 相关文献

参考文献12

  • 1吴爱萍,潘纯,郭风梅,邱海波.呼吸机管路更换对呼吸机相关肺炎影响的荟萃分析[J].中华急诊医学杂志,2012,21(6):587-591. 被引量:9
  • 2呼吸机相关性肺炎诊断、预防和治疗指南(2013)[J].中华内科杂志,2013,52(6):524-543. 被引量:1175
  • 3David R, Park MD. The microbiology of ventilator associated - pneumonia[J]. Respir Care, 2005, 50(6): 742-763.
  • 4Safdar N, Cmich C J, Maki DG. The pathogenesis of ventilator as- sociated - pneumonia: its relevance to developing effective strate- gies for prevention[J]. Respir Care, 2005, 50(6) : 725 -739.
  • 5刘汉,倪海滨,刘颖.呼吸机相关性肺炎集束化治疗的临床意义[J].中华急诊医学杂志,2009,18(2):190-192. 被引量:34
  • 6陈民钧,王辉,中国医院内病原菌耐药监测网.中国重症监护病房革兰阴性菌耐药性连续7年监测研究[J].中华医学杂志,2003,83(5):375-381. 被引量:504
  • 7Corbella X, Montero A, Pujol M, et 81. Emergence and rapid spread of carbapene resistance during a large and sustained hospi- tal outbreak of multiresistant Acinetobacter haumannii[ J]. J Clin Microbiol, 2000, 38( 11 ) : 4086 -4095.
  • 8Han J, Liu Y. Effect of ventilator circuit changes on ventilator - associated pneumonia: a systematic review and meta - analysis [J]. Respir Care, 2010, 55(4) : 467 -474.
  • 9Han JN, Liu YP, Ma S, et al. Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventila- tor-associated pneumonia in a Beijing hospital[ J ]. Respir Care, 2001,46(9) : 891 -896.
  • 10Kola A, Eckmanns T, Gastmeire P. Efficacy of heat and mois- ture exchangers in preventing ventilator - associated pneumonia: meta -analysis of randomized controlled triMs[J]. Intensive Care Med, 2005, 31:5-11.

二级参考文献66

同被引文献156

  • 1高冬娜,张彧.中性粒细胞弹性蛋白酶与急性肺损伤[J].中国急救医学,2006,26(3):210-212. 被引量:8
  • 2郑蕴欣,蔡圣浩.医院呼吸机的科学化配置[J].中国医疗器械杂志,2006,30(3):222-223. 被引量:1
  • 3孙树梅,李琼,王茵茵,张亚莉,汪能平.发生呼吸机相关性肺炎的高危因素及病原菌分析[J].中华医院感染学杂志,2006,16(8):882-884. 被引量:87
  • 4医院感染管理办法 中华人民共和国卫生部令第48号[J].卫生政策,2006(9):13-15. 被引量:5
  • 5杨晶,邵杰敏,张爱丽,韩晓雯.炎症因子与慢性阻塞性肺疾病[J].临床荟萃,2007,22(12):911-912. 被引量:21
  • 6张波.急危重症护理学[M]3版.北京:人民卫生出版社,2012:16.
  • 7Lorente L, Lecuona M, Galvn R, ct al. Periodically changing ventilator circuits is not necessary to prevent ventilator-assnciated pneumonia when a heat and moisture exchanger is used [J]. Infect Control Hosp Epidemiol, 2004, 25 (12): 1077-1082. DOI: 10.1086/502347.
  • 8Masterton RG, Galloway A, French G, et al. Guidelines for the management of hospital-acquired pneumonia in the UK: report of the working party on hospital-acquired pneumonia of the British Society for Antimicrobial Chemotherapy [J]. J Antimicrob Chemother, 2008, 62 (1): 5-34. DOI: 10.1093/jac/dkn162.
  • 9Han J, Liu Y. Effect of ventilator circuit changes on ventilator- associated pneumonia: a systematic review and meta-analysis [J]. Respir Care, 2010, 55 (4): 467-474.
  • 10Han JN, Liu YP, Ma S, et al. Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator- associated pneumonia in a Beijing hospital [J]. Respir Care, 2001, 46 (9): 891-896.

引证文献26

二级引证文献99

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部