期刊文献+

温控阀导致的压缩机联锁停车故障分析 被引量:1

Failure analysis of interlock and shutdown of compressor caused by temperature control valve
下载PDF
导出
摘要 某LLDPE装置的两台往复式氮气压缩机,在春季试车后运行一直正常,但是进入夏季后,频繁出现润滑油压力报警,导致压缩机联锁停车的事故。通过分析,得出了温控阀非正常动作是造成润滑油供油压力报警和联锁机组停车的原因,最终发现温控阀的冷热油管路误接,并解决了问题。 The two reciprocating nitrogen-gas compressors of LLDPE plant work normally after test run in the spring. But in the summer, the oil pressure alarm is activated frequently, which cause the compressor stop with interlock. Through the analysis, we find out the reason that the abnormal movements of temperature control valve causes the alarm of oil pressure and interlock the compressor stopping. Finally, we found the pipeline misconnection of hot oil and cold oil of temperature control valve, and solve the problem at last.
作者 雷鸣
出处 《机械》 2015年第3期77-80,共4页 Machinery
关键词 温控阀 温度 压力 压缩机 temperature control valve temperature pressure compressor
  • 相关文献

参考文献2

二级参考文献5

共引文献11

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部