期刊文献+

GMAW用焊材复验技术

Study on the retest technique of welding material for GMAW
下载PDF
导出
摘要 在化学分析、RT检测、全焊缝金属拉伸实验、冲击等实验基础上,分析了影响焊材复验结果的各种因素,并从保护气体、焊接规范参数以及母材与焊材的匹配性选择等方面给出了具体解决方法,为GMAW焊材复验工作提供了实用的技术方案。 Based on chemical analysis, RT, all-weld-metal tensile test and impact test, various factors that influence the retest result of welding material are analyzed in this paper,and the solutions to the choice of shielding gas,welding procedure parameters and the matching selection of base material and welding material are given,which will provide practical technical solution for retest work of welding material for GMAW.
出处 《电焊机》 2015年第2期143-146,共4页 Electric Welding Machine
关键词 GMAW 焊材 复验 GMAW welding material retest
  • 相关文献

参考文献2

二级参考文献7

  • 1吕向阳 等.高强钢氢陷形为的定量研究[A].中国机械工程学会焊接学会编.第六届全国焊接学会论文集[C].西安:中国机械工程学会焊接学会,1990.26~29.
  • 2可兹洛夫PA.焊接船体钢时的氢[M].北京:科学出版社,1973.70-80.
  • 3Wang S H, Luu W C, et al. Hydrogen permeation in a submerged arc weldment of TMCP steel[J]. Materials Chemistry and Physics,2003,77(2) :447 -454.
  • 4Wildash C, Cochrane R C,Gee R. Simulation of hydrogen induced cold cracking using dectrolytic prechatging procedure[J]. Science and Technology of Welding & Joining,2001,6(2) :73-78.
  • 5Mirza R M, Gee R. Effects of shielding gases on weld diffusible hydrogen contents using cored wires[J].Science and Technology of Welding & Joining, 1999, 4(2) : 104-111.
  • 6Liu S, Olson D L. The role of inclusions in controlling HLSA steel weld microstructures[J ]. Welding Journal,1986(6) : 139- 148.
  • 7杜则裕,张德勤,田志凌.低碳低合金钢焊缝金属的显微组织及其影响因素[J].钢铁,1999,34(12):67-71. 被引量:29