期刊文献+

土壤中氡浓度的快速测定 被引量:2

Rapid Determination of Radon Concentration in Soil
下载PDF
导出
摘要 为减少被动积累法测定土壤中氡浓度的测量时间,探讨了一种快速测量土壤氡浓度的方法。该方法将未平衡时的测量结果通过最小二乘法拟合得到相关参数值,进而得到平衡时的土壤氡浓度。方法研究中,研制了一台土壤氡浓度快速测量仪。实验室和现场测量结果表明,拟合值和平衡时的氡浓度值之间的相对偏差在7%以下,测量时间缩短3h以上。 To reduce the time for measuring radon concentration in soil by passive accumulation method,a rapid method has been studied. The method can provide related parameter values that fitted from unbalanced result by least square method and then get the balanced radon concentration. On account of above conditions,a rapid measuring instrument for radon concentration in soil has been researched. Measured results show that the relative deviation between the fitting values and the balanced values is below 7%,measuring time is shorten more than 3 hours than before.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2014年第11期1316-1319,共4页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金项目(11275096)资助
关键词 土壤氡浓度 快速测量 最小二乘法 radon concentration in soil rapid measurement least square method
  • 相关文献

参考文献3

二级参考文献15

共引文献19

同被引文献13

  • 1张谷春.土壤中氡浓度测量的工作体会[J].能源技术与管理,2006(5):60-60. 被引量:3
  • 2陈锡辉,张银鸿.LabVlEW8.20程序设计从人门到精通[M ].北京:清华大学出版社,2007.
  • 3Miroslaw Janik,Shinji Tokonami, Tibor Kov6cs,etal. International inter - comparisons of integrating ra-don detectors in the NIRS radon chamber[ J]. AppliedRadiation and Isotopes, 2009, 67(9) :1691 -1696.
  • 4MishraR, Mayya Y S. Study of a deposition - baseddirect thoron progeny sensor (DTPS) technique for es-timating equilibrium equivalent thoron concentration(EETC) in indoor environment [ J ]. Radiat Meas,2008, 43:1408 -1416.
  • 5Zhuo W, Tokonami S,Yonehara H, et al. A simplepassive monitor for integrating measurements of indoorthoron concentrations [ J ]. Rev Sci Instrum,2002,73:2877.
  • 6KarunakaraN, Sudeep Kumara K, Yashodhara I, etal. Evaluation of radon adsorption characteristics of acoconut shell - based activated charcoal system for ra-don and thoron removal applications [ J ]. Journal ofEnvironmental Radioactivity, 2015, 142:87 - 95.
  • 7Voltaggio M, Spadoni M. Determination of 222Rn inwater by absorption in polydimethylsiloxane mixed withactivated carbon and gamma - ray spectrometry : Anexample application in the radon budget of Patemosubmerged sinkhole (Central Italy) [J]. Applied Ge-ochemistry ,2013, 34: 65 -74.
  • 8VanDeynse A, Cosma C,Poffijn A, A passive radondosimeter based on the combination of a track etch de-tector and activated charcoal[J]. Radiation Measure-ments, 1999,31:325 -330.
  • 9Dimova N,Burnett WC, Lane - Smith D. Improvedautomated analysis of radon ( 222 Rn) and thoron(220Rn) in natural waters [ J ].,2009 , 43 ( 22):8599 -603.
  • 10肖德涛,李志强,赵桂芝,等.一种自动消除PIPScx能谱峰温度漂移的方法及装置[J].中国专利:2014102084779,2014.