期刊文献+

环境风对中庭自然排烟效果的影响研究 被引量:4

Study on influence of wind on the natural smoke exhaust of atrium
下载PDF
导出
摘要 针对建筑火灾中环境风作用下自然排烟的问题,设置了不同的火灾场景,运用FDS软件模拟了火灾时步行街中庭内不同场景的烟气蔓延情况,分析了自然排烟窗的开启面积为26%,分别采用顶部、侧面及顶部加侧面3种开启方式在无风、风速5.6m/s和风速11.2m/s的条件时的火灾场景,获得了烟气温度、能见度和CO体积分数等参数,并对各个场景下的自然排烟效果进行了分析。结果表明,无风时,三种自然排烟方式的效果相差不大,外界侧向风对中庭侧窗自然排烟的影响较大。 Different fire scenarios were set to solve the natural smoke exhaust problem of building fire under environmental wind, and FDS was introduced to analysis the smoke movement during the building fire such as pedestrian street in the atrium. Three fire scenarios were designed, they have the same natural smoke exhaust windows as an open area 26%, and the open mode were set as top, side, and top-side, and the wind speed was set as 0, 5.6, 11.2 m/s. The flue gas temperature, visi- bility, the concentration of CO, and natural smoke exhaust effect of the various scenarios were simulated and analyzed. The results demonstrated that the three smoke exhaust modes with- out wind have no obvious difference, but the side wind has a huge effect on the side window natural smoke exhaust.
作者 孙亮 黄文丽
机构地区 宁波市消防支队
出处 《消防科学与技术》 CAS 北大核心 2015年第3期329-332,共4页 Fire Science and Technology
关键词 环境风 自然排烟 中庭 数值模拟 建筑防火 surrounding wind natural smoke exhaust atrium numerical simulation building fire protection
  • 相关文献

参考文献6

二级参考文献31

  • 1童朝阳,阴忆烽,黄启斌,林福生.火灾烟气毒性的定量评价方法评述[J].安全与环境学报,2005,5(4):101-105. 被引量:27
  • 2王智勇,张少辉.影响高层建筑内热烟气流动的因素分析[J].武警学院学报,2006,22(4):22-23. 被引量:3
  • 3Klote J H,Milke J A.Design of Smoke Management Systems[M].Atlanta:ASHRAE,2002.
  • 4NFPA 204,Standard for Smoke and Heat Venting[S].National Fire Protection Association,Quincy,MA,2002.
  • 5Chow W K,Li J.Wind effects on performance of static smoke exhaust systems:horizontal ceiling vents[J].ASHRAETransactions,2004,(110):479-488.
  • 6The Chartered Institution of Building Services Engineers Delta House. CIBSE.
  • 7S.M. Hockey and P. J. Rew, " Human Response to Thermal Radiation" Contract Research Report No. 97/ 1996, HSE books, Sudbury Suffolk, UK(1996).
  • 8D.A. Purser, Polymer International, 47, p. 1232(2000).
  • 9D.A. Purser, "Toxicity assessment of combustion products". SFPE Handbook of Fire Protection Engineering. , National Fire Protection Association, Quincy, Massachusetts, Third edition,2002:2-6.
  • 10BS DD240: 1997, Fire Safety Engineering in Buildings.

共引文献107

同被引文献18

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部