期刊文献+

单切口经阴道可调节AjustTM吊带治疗女性压力性尿失禁16例临床分析 被引量:2

A single incision adjustable sling-the AjustTM system for the treatment of female stress urinary incontinence:clinical analysis of 16 cases
原文传递
导出
摘要 目的 评估AjustTM吊带系统手术治疗女性压力性尿失禁(SUI)的安全性和疗效.方法 2013年4月-2013年11月共收集SUI患者16例,应用单切口可调节AjustTM吊带系统进行治疗,记录并分析所有患者的临床资料,包括治愈率、满意度和手术并发症等.结果 16例手术均获得成功,手术时间为9- 17min,失血量10 -35mL,平均18±4.5mL.膀胱等盆腔脏器及尿道无损伤,围手术期无会阴血肿的发生,无切口感染发生.16例尿失禁均消失,随访半年无复发.结论 单切口A justTM吊带治疗SUI创伤小,并发症少,疗效良好. Objectives To evaluate the efficacy and safety of the AjustTM system for the treatment of femalestress urinary incontinence(SUI).Methods From Apr 2013 to Nov 2013,16 cases of female patients with stress urinary incontinence in our hospital were enrolled in the study.All patients with primary urodynamic SUI were prospectively selected to receive the adjustable single incision AjustTM procedure,the clinical data was recorded and analyzed,inchided objective and subjective cure rate and operative complications.Results All 16 patients successfully completed the operation,operation success rate was 100%.The operative duration was 10-35 minx,the blood loss ranged from 10-35 ml.During the operation,there no bladder or urethral injury,no intestinal or vaginal injury,no perineum haematoma or incision infection,no voiding dysfunction or denovo urgency appeared.All of the 16 cases SUI were cured.With a follow-up from 6 months,no one recurrence.Conclusions The adjustable single incision AjustTM system was a minimally invasive technique for the treatment of female SUI and with fewer complications,the efficacy of AjustTM was good in a short term follow-up.
出处 《国际泌尿系统杂志》 2015年第2期236-239,共4页 International Journal of Urology and Nephrology
关键词 尿失禁 压力性 阴道 Urinary Incontinence,Stress Vagina
  • 相关文献

参考文献6

  • 1郝燕菲,孙秀丽,王建六.问卷调查在采集女性盆腔脏器脱垂患者病史中的应用[J].国际妇产科学杂志,2011,38(5):446-448. 被引量:8
  • 2DeLancey J0. Structural support of the urethra as it relates to stress urinary incontinence: the hammock hypothesis [ J ]. Am J Obstet Cynecol,1994,170 (6) :1713 - 1720.
  • 3张雪培,任选义,魏金星,王智勇,江雪霞,刘建华.单切口可调节Ajust^(TM)吊带治疗女性压力性尿失禁初步研究[J].临床泌尿外科杂志,2012,27(12):916-919. 被引量:7
  • 4Kyu SI, Myung SC, Chin KD, et al. The long term( 5 - yea) objec- tive TVT success rate does not depend on predictive factors at muh- ivariate analysis : a muhicentre retrospective study [ J ]. Eur Urol, 2008,53 : 176 - 183.
  • 5Latthe PM,Singh P,Foon R,et al. Two routes of transobturator tape procedures in stress urinary incontinencc:a metes analysis with di- rect and indirect comparison of randomized trials [ J ]. BJU lnt, 2010,106:68 - 76.
  • 6Mosta A, Agur W, AbdeI -AI1 M, et aI. A multicentre prospec- tive randomized study of single - incision mini - sling (Ajust) ver- sust ension -free vaginal tape -obturator( TVT- OTM)in theman- agement of female stress urinary incontinence: pain profile and short - term outcomes [ J ]. Eur J Obstet Gynecol Repmd Blol,2012,165:115 -121.

二级参考文献15

  • 1杨欣,毛卓.女性肛门失禁发病机制及其诊治策略[J].中国实用妇科与产科杂志,2006,22(8):638-640. 被引量:8
  • 2Douglas A.Drossman,蒋晓玲(译),萧树东(校).罗马Ⅲ:新的标准[J].胃肠病学,2006,11(12):705-707. 被引量:513
  • 3王建六.妇科泌尿学与盆底重建外科[M].第3版.北京:人民卫生出版社.2008:297-298.
  • 4Weber M,Abrams P,Brubaker L,et al. The standardization of terminology for researchers in female pelvic floor disorders [J]. Int Urogynecol J Pelvic Floor Dysfunct, 2001,12 (3) : 178-186.
  • 5KYU S L, MYUNG S C, CHIN K D, et al. The long term (5-years) objective TVT success rate does not depend on predictive factors at multivariate analysis: a multicentre retrospective study[J]. Eur Urol, 2008, 53:176-183.
  • 6LATTHE P M, SINGH P, FOON R, et al. Two routes of transobturator tape procedures in stress urinary incontinence: a meta-analysis with direct and indirect comparison of randomized trials[J]. BJU Int, 2010, 106:68-76.
  • 7MOLDEN S M, LUCENTE V R. New minimally invasive slings: TVT Secur[J]. Curr Urol Rep, 2008, 9:356-361.
  • 8BACARAT F, IGLESIAS R, PESSOA R, et al. Unfavorable immediate outcome of the TVT secure sling in twenty consecutive women with stress urinary in continence[abstract 1566][J]. J Urol, 2008, 179 (Supp 1) :535-536.
  • 9SONG K, PARK J, HAN J Y, et al. The initial experience of TVT-S procedure in female stress urinary incontinence patients [abstract P-36] [J]. Korean J Urol, 2008, 49 (Suppl 1):36.
  • 10URWIN G H, HEATON S R. The MiniArc(TM) single-incision sling system for female stress urinary incontinence: early results[J]. Bju Int, 2008, 101:26 -26.

共引文献12

同被引文献22

  • 1ZHANG L, ZHU L, XU T, et al. A Population-based survey of the prevalence, bother of lower [J]. Eur Urol, potential risk factors, and symptom-specific urinary tract symptoms in adult Chinese women 2015, 68(1): 97-112.
  • 2DELANCEY J O. Structural support of the urethra as it relates to stress urinary incontinence: the hammock hypothesis[J]. Am J Obstet Gynecol, 1994, 170(6).. 1713-1723.
  • 3ULMSTEN U, HENRIKSSON L, JOHNSON P, et al. An am- bulatory surgical procedure under local anesthesia for treatment of female urinary incontinence[J]. Int Urogynecol J Pelvic Floor Dysfunct, 1996, 7(2): 81-86.
  • 4MOLDEN S M, LUCENTE V R. New minimally invasive slings: TVT Secur[J]. Curt Urol Rep, 2008, 9(5): 358-361.
  • 5ABDEL-FATTAH M, AGUR W, ABDEL-ALL M, et al. Pro- spective multi-centre study of adjustable single-incision mini- sling (AjustTM ) in the management of stress urinary inconti- nence in women: 1-year follow-up study[J]. BJU Int, 2012, 109(6) : 880-886.
  • 6BOYERS D, KILONZO M, MOSTAFA A, et al. Comparison of an adjustable anchored single-incision mini-sling, AjustTM, with a standard mid-urethral sling, TVT-OTM : a health econom- icevaluation[J]. BJUlnt, 2013, 112(8): 1169-1177.
  • 7MOSTAFA A, AGUR W, ABDEL-ALL M, et al. A multicen- tre prospective randornised study of single-incision mini-sling (AjustTM) versus tension-free vaginal tape-obturator (TVT-O) in the management of female stress urinary incontinence pain profile and short-term outcomes[J]. Eur J Obstet Gynecol Re- prod Biol, 2012, 165(1): 115-121.
  • 8ABDEL-FATTAH M, FORD J A, LIM C P, et al. Single-inci- sion mini-slings versus standard midurethral slings in surgical management of female stress urinary incontinence a meta-analy- sis of effectiveness and eomulications [J]. Eur Urol. 2011. 60(3): 468-480.
  • 9HUBKA P, NANKA O, MARTAN A, et al. Fixation of the ajust minisling based upon cadaveric study[J]. Int Urogynecol J, 2013, 24(12): 2119-2123.
  • 10KAWAGUCHI M, HASHIZUME K, IWATA T, et al. Percu- taneous radiofrequency lesioning of sensory branches of the ohtu- rator and femoral nerves for the treatment of hip joint pain[J]. Reg Anesth Pain Med, 2001, 26(6): 576-581.

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部