摘要 To develop a robot system for minimally invasive surgery is significant,however the existing minimally invasive surgery robots are not applicable in practical operations,due to their limited functioning and weaker perception.A novel wire feeder is proposed for minimally invasive vascular interventional surgery.It is used for assisting surgeons in delivering a guide wire,balloon and stenting into a specific lesion location.By contrasting those existing wire feeders,the motion methods for delivering and rotating the guide wire in blood vessel are described,and their mechanical realization is presented.A new resistant force detecting method is given in details.The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire.The driving torque for rotating the guide wire is developed at different positions.Using the CT reconstruction image and extracted vessel paths,the path equation of the blood vessel is obtained.Combining the shapes of the guide wire outside the blood vessel,the whole bending equation of the guide wire is obtained.That is a risk criterion in the delivering process.This process can make operations safer and man-machine interaction more reliable.A novel surgery robot for feeding guide wire is designed,and a risk criterion for the system is given. To develop a robot system for minimally invasive surgery is significant,however the existing minimally invasive surgery robots are not applicable in practical operations,due to their limited functioning and weaker perception.A novel wire feeder is proposed for minimally invasive vascular interventional surgery.It is used for assisting surgeons in delivering a guide wire,balloon and stenting into a specific lesion location.By contrasting those existing wire feeders,the motion methods for delivering and rotating the guide wire in blood vessel are described,and their mechanical realization is presented.A new resistant force detecting method is given in details.The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire.The driving torque for rotating the guide wire is developed at different positions.Using the CT reconstruction image and extracted vessel paths,the path equation of the blood vessel is obtained.Combining the shapes of the guide wire outside the blood vessel,the whole bending equation of the guide wire is obtained.That is a risk criterion in the delivering process.This process can make operations safer and man-machine interaction more reliable.A novel surgery robot for feeding guide wire is designed,and a risk criterion for the system is given.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第2期249-257,共9页 中国机械工程学报(英文版)
基金 Supported by National Hi-tech Research and Development Program of China(863 Program,Grant No.2010AA044001) Hebei Provincial Natural Science Foundation of China(Grant No.E2015203405)
关键词 minimally invasive wire feeder force analysis moment of inertia risk criterion minimally invasive wire feeder force analysis moment of inertia risk criterion
  • 相关文献

参考文献2

二级参考文献10

  • 1Gomes E Surgical robotics: Reviewing the past, analysing the present, imaging the future[J]. Robotics and Computer- Integrated Manufacturing, 2011, 27(2): 261-266.
  • 2Ramcharitar S, Patterson M S, Jan van Geuns R, et al. Technology insight: Magnetic navigation in coronary interventions[J]. Nature Clinical Practice Cardiovascular Medcine, 2008, 5(3): 148-156.
  • 3Ikuta K, Ichikawa H, Suzuki K, et al. Multi-degree of freedom hydraulic pressure driven safety active catheter[C]//IEEE International Conference on Robotics and Automation. Piscataway, NJ, USA: IEEE, 2006: 4161-4166.
  • 4Haga Y, Tanahashi Y, Esashi M. Small diameter active catheter using shape memory alloy[C]//11th Annual International Workshop on Micro Electro Mechanical Systems. 1998: 419-424.
  • 5Ganji Y, Janabi-Sharifi E Catheter kinematics for intracardiac navigation[J]. IEEE Transactions on Biomedical Engineering, 2009, 56(3): 621-631.
  • 6Fang B K, Ju M S, Lin C C K. A new approach to develop ionic polymer-metal composites (IPMC) actuator: Fabrication and control for active catheter systems[J]. Sensors and Actuators A: Physical, 2007, 137(2): 321-329.
  • 7Feng W X, Chi C M, Wang H R, et al. Highly precise catheter driving mechanism for intravascular neurosurgery[C]//IEEE International Conference on Mechatronics and Automation. Piscataway, NJ, USA: IEEE, 2006: 990-995.
  • 8Arai E Fujimura R, Fukuda T, et al. New catheter driving method using linear stepping mechanism for intravascular neu- rosurgery[C]//IEEE International Conference on Robotics and Automation, vol.3. Piscataway, NJ, USA: IEEE, 2002: 2944- 2949.
  • 9Jayender J, Patel R V, Nikumb S. Robot-assisted catheter insertion using hybrid impedance control[C]//IEEE International Conference on Robotics and Automation. Piscataway, N J, USA: IEEE, 2006: 607-612.
  • 10Ganji Y, Janabi-Sharifi F, Cheema A N. Robot-assisted catheter manipulation for intracardiac navigation[J]. International Journal of Computer Assisted Radiology and Surgery, 2009,4(4): 307-315.