摘要 The friction drive elevators the influence of the braking distance has very high significance to meet certain safety regulations and comfort.During the emergency braking the delay for the system a frame and a cabin should be within the range from 0.2 to 9.81 m/s~2.However,there are no specialist literatures regarding the issues connected with emergency braking of elevating devices either.The results of the own empirical research work are presented regarding the influence of design changes on the working parameters of the friction drive elevator gears.ASG100,KB 160,PP16,PR2000UD and CHP2000 types of safety progressive gears are analyzed.ASG100,KB 160,PP16,PR2000UD type progressive gears are already produced by European manufacturers.CHP2000 type gears are established as the alternative option for the already existing solutions.The unique cam system has been used in the CHP 2000 gears.The cam leverage gives the chance to unblock,in a very easy way,the clamed gears after braking.Thus,it is a key aspect to perform laboratory tests over the braking process of a newly created solution.The proper value of the braking distance has a significant influence on the value of delay in terms of binding standards.The influence of loading on the effective braking distance and the value of the falling elevator cabin speed are analyzed and the results are presented.The results presented are interesting from lift devices operation and a new model of CHP 2000progressive gear point of view. The friction drive elevators the influence of the braking distance has very high significance to meet certain safety regulations and comfort.During the emergency braking the delay for the system a frame and a cabin should be within the range from 0.2 to 9.81 m/s^2.However,there are no specialist literatures regarding the issues connected with emergency braking of elevating devices either.The results of the own empirical research work are presented regarding the influence of design changes on the working parameters of the friction drive elevator gears.ASG100,KB 160,PP16,PR2000UD and CHP2000 types of safety progressive gears are analyzed.ASG100,KB 160,PP16,PR2000UD type progressive gears are already produced by European manufacturers.CHP2000 type gears are established as the alternative option for the already existing solutions.The unique cam system has been used in the CHP 2000 gears.The cam leverage gives the chance to unblock,in a very easy way,the clamed gears after braking.Thus,it is a key aspect to perform laboratory tests over the braking process of a newly created solution.The proper value of the braking distance has a significant influence on the value of delay in terms of binding standards.The influence of loading on the effective braking distance and the value of the falling elevator cabin speed are analyzed and the results are presented.The results presented are interesting from lift devices operation and a new model of CHP 2000progressive gear point of view.
作者 LOONKWIC Poul
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第2期363-368,共6页 中国机械工程学报(英文版)
基金 Nova Trading Company from Torun and Rywal-RHC Company from Lublin for the financial support owing to which it was possible to perform the research study and tests presented in the compilation.
关键词 lift gears friction drive progressive safety gears braking distance emergency braking lift gears friction drive progressive safety gears braking distance emergency braking
  • 相关文献

参考文献1

二级参考文献10

  • 1李醒飞,张晨阳,李立京,张国雄,郭丽峰.电梯导轨对轿厢振动的影响[J].中国机械工程,2005,16(2):115-118. 被引量:25
  • 2傅武军,廖小波,朱昌明.基于ADAMS的电梯横向振动频域分析及参数优化[J].系统仿真学报,2005,17(6):1500-1504. 被引量:19
  • 3INABA H, SHIGETA M, ANDO T, et al. Attitude control system of a super-high speed elevator car based on magnetic guides[C]// International Conference on Industrial Electronics, Control, and Instrumentation. Proceedings of the 20th International Conference on Industrial Electronics, Control and Instrumentation, September 5-9, 1994 Bologna, Italy. New York: IEEE, 1994: 1028-1033.
  • 4SISSALA M, HEIMOLA T, OTALA M. Optimization of lift car vibrational behaviour by modal analysis[J]. Elevator World, 1985, 33( 6): 39-43.
  • 5KENJI U, KEN-ICHI O. Active roller guide system for high-speed elevators[J]. Elevator World, 2002, 50(4): 86-93.
  • 6MUTOH N. Horizontal vibration suppression method suitable for super-high-speed elevators[J]. Electrical Engineering in Japan, 1999, 129(1): 59-73.
  • 7KENJI U, KENICHI O, TAKASHI Y. Elevator vibration reducing device: USA, 20040020725A 1 [P]. 2004-02-05.
  • 8WEE H, KIM Y Y, JUNG H, et al. Nonlinear rate-dependent stick-slip phenomena: modeling and parameter estimation[J]. International Journal of Solids and Structures, 2001, 38(8): 1415-1431.
  • 9LI Q, YOSHIMURA T, HINO J. Active suspension with preview of large-sized buses using fuzzy reasoning[J]. Int. J. of Vehicle Design, 1998, 19(2): 187-198.
  • 10ZHANG Liping. Hydraulic transmission system and design[M]. Beijing: China Machine Press, 2005.

同被引文献12

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部