期刊文献+

基于支持向量机的逆变电源故障诊断 被引量:6

Fault diagnosis of inverter power supply device based on SVM
下载PDF
导出
摘要 针对基于支持向量机的逆变电源故障诊断进行了研究。使用自行设计的变频电源模拟逆变器各种故障状态,分别采集了常态和各种故障状态下的电压信号,并进行波形和谐波分析。并在MATLAB中搭建了逆变电源的仿真电路用来验证实际电路实验。在电压波形和谐波分析的基础上,研究一种根据电压波形特征进行逆变电源故障诊断的方法,即采用支持向量机分类的方法对逆变器的故障状态进行分类。仿真实验和真实试验验证了基于支持向量机的逆变器故障诊断方法的有效性。 In this paper , a method of fault diagnosis of inverter power supply device based on SVM is studied and a kind of variable frequency power supply device simulating various fault states of Inverter power supply is designed . The voltage waveform of inverter power supply in the normal state and in various fault states is measured and analyzed . The simulation experiment in Simulink of MATLAB is set up to testify the actual experiment .On the foundation of the analyzing of the voltage waveform and quality of the power , a method about fault diagnosis according to the voltage waveform is put forward , i.e.the fault states of inverter are classified through a method of fault diagnosis based on SVM.At last, the SVM method is validated accuracy through experiments .
出处 《电测与仪表》 北大核心 2015年第5期45-51,共7页 Electrical Measurement & Instrumentation
基金 上海市科委科技创新行动计划(13dz1202800) 交通运输部应用基础研究项目(201332918350) 国家自然科学基金资助项目(5210914) 上海海事大学研究生创新基金资助项目(YXR2014059)
关键词 故障诊断 支持向量机 逆变电源 电能质量分析 fault diagnosis SVM variable frequency power supply power quality analysis
  • 相关文献

参考文献2

二级参考文献16

  • 1王雪,付振波.采用小波分析与支持向量机的车轮踏面擦伤识别方法[J].中国机械工程,2004,15(18):1641-1643. 被引量:8
  • 2许珉,张鸿博.基于Blankman-harris窗的加窗FFT插值修正算法[J].郑州大学学报(工学版),2005,26(4):99-101. 被引量:45
  • 3周俊,王小海,祁才君.基于Blackman窗函数的插值FFT在电网谐波信号分析中的应用[J].浙江大学学报(理学版),2006,33(6):650-653. 被引量:58
  • 4Jain VK, ColIins WL, DaVis DC. High-accuracy Analog Measurements Via Interpolated FFF. IEEE Transactions on Instrumentation and Measurement, 1979, 28(2): 113-122.
  • 5Harris [J]. On the Use of Windows for Harmonic Analysis with the Discrete Fourier Transform. Proceedings of the IEEE, 1978, 66(1): 51-83.
  • 6TMS320F28335 , TMS320F283 34, TMS320F28332 Digital Signal Controllers, 2007.
  • 7彭启碌,管庆.DSP集成开发环境-CCS及DS/BIOS的原理与应用[M].北京:电子工业出版社,2005.
  • 8Platt M.Sequential minimal optimization:a fast algorithm for training support vector machine. Advances in kernel methods-support vector learing . 1999
  • 9Vapnik V N.Statistical Learning Theory. . 1998
  • 10Modell D,,Donnald J.Data.Acquisition and Wheel Inspection Methodol-ogies Using Eddy Current Sensors. Instrumentation in the Aerospace In-dustry:Proceedings of the International Symposium . 1994

共引文献12

同被引文献46

  • 1吴明强,史慧,朱晓华,肖开清.故障诊断专家系统研究的现状与展望[J].计算机测量与控制,2005,13(12):1301-1304. 被引量:68
  • 2Peuget R, Courtine S, Rognon J P. Fault detection and isolation on a PWM inverter by knowledge baed model [J] . IEEE Trans- actions on Industry Applications, 1998, 34 (6) : 1318 - 1326.
  • 3Mendes A M S, Cardoso A J M. Voltage source inverter fault diag- nosis in variable speed AC drives by the average current Park's Vec- tor approach [A . IEEE International Electric Machines and Drives Conference [C . Madison, USA, 1999.
  • 4Abramik S, Sleszynski W, Nieznanski J, et al. A diagnostic meth- od for on-line fault detection and localization in VSI- fed AC drives [A]. Proceedings of the 10th European Conference on Pow- er Electronics and Applications [C] . Toulouse, France.
  • 5Karimi S, Gaillard A, Poure P, et al. FPGA-based real-time power converter failure diagnosis for wind energy conversion sys terns [J]. IEEE Transactions on Industrial Electronics, 2008, 55 (12): 4299-4308.
  • 6Cruz S M A, Ferreira M, Cardoso A J M. Output error voltages a first method to detect and locate faults in matrix converters FA]. Proceedings of the 3th Annual Conference of IEEE Industrial Elec- tronics [C . Orlando, Florida, USA, 2009: 1319- 1325.
  • 7Kwak S, Kim T. Fault detection and location of open circuited switch faults in matrix converter drive systems [A]. Proceedings of the IEEE Vehicle Power and Propulsion Conference EC . Dear- born, MI, USA, 2009: 1476-1481.
  • 8Iov F, Blaabjerg F, Ries K. IGBT fuses in voltage source converters [A]. Proceedings of the PCIM [C] . Chicago, IL, USA, 2001: 267 - 276.
  • 9Karimi S, Gaillard A, Poure P, et al. FPGA based real - time power converter failure diagnosis for wind energy conversion sys terns [J]. IEEE Transactions on Industrial Electronics, 2008, 55 (12) : 4299 -4308.
  • 10Won-Sang Im, Jang Kim, Dong-Choon Lee, Kyo-Beum. Diag- nosis and Fault-Tolerant Control of Three-Phase AC - DC PWM Converter Systems[J]. IEEE transactions on industry applications, 2013,49(4) :1539-1547.

引证文献6

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部