摘要 对C80高强混凝土经受100~700℃高温作用后的氯离子渗透性进行试验研究。对比未掺加聚丙烯纤维的素混凝土,以分析掺加聚丙烯纤维是否对高强混凝土高温作用后氯离子的渗透性有所影响。并得出结论:作用温度在100~200℃时,掺入聚丙烯纤维会提高高强混凝土的氯离子渗透性,作用温度在300~400℃时反之,其余温度下影响不大。 It studied the chloride permeability of C80 high performance concrete affected by high temperatures between 100-700 ℃. Comparing with the plain concrete that didn't mixed with polypropylene fiber,we mixed polypropylene fiber,to analyze if the mixture of polypropylene fiber have any influence on the chloride permeability of high performance concrete under high temperature,It finally draw an conclusion that the mixture of polypropylene fiber would enhance the chloride permeability when the temperature ranged from 100- 200 ℃ and had an opposite effect when the temperature ranged from 300-400 ℃,whereas had little influence under the higher temperature.
出处 《混凝土》 CAS 北大核心 2015年第3期87-89,共3页 Concrete
基金 国家自然科学基金资助项目(51278325) 山西省自然科学基金项目(2011011024-2)
关键词 聚丙烯纤维 高强混凝土 高温 氯离子渗透性 polypropylene fiber high performance concrete high temperature chloride permeability
  • 相关文献

参考文献8

二级参考文献43

  • 1肖建庄,王平.掺聚丙烯纤维高性能混凝土高温后的抗压性能[J].建筑材料学报,2004,7(3):281-285. 被引量:31
  • 2库马·梅塔,保罗JM蒙特罗.混凝土:微观结构、性能和材料[M].覃维祖,王栋民,丁建彤译.北京:中国电力出版社,2008.
  • 3Ulm F J, Acker P,Levy M. Chunnel Fire. II: Analysis of Concrete Damage[J]. Journal of Engineering Mechan-ics, 1999,125(3) :283-289.
  • 4Hongxiu Du, Yixiao Qin, Wei Zhang. Mechanics performance of high-performance concrete with polypropylene fibers [J]. Applied Mechanics and Materials,2011,(99-100) : 1233-1238.
  • 5M.C.R.Farage,J.Sereombe,C.Galle,Rehydration and microstructure of cement paste after heating at temperatures up to 300℃,Cement and Concrete Research,33(2003)1047-1056.
  • 6Final Report by RILEM TC 116-PCD.Conerete Durability-An Approaeh towards performance Testing.Materials and Structures.April 1999.
  • 7[美]陈惠发等著.混凝土和土的本构方程.北京:中国建筑工业出版社,2004.
  • 8T.Z.Harmathy,Thermal properties of concrete at elevated temperatures,ASTM Journal of Materials,5(1970):47-74.
  • 9R.Lachaudm Le comportement du ciment a la chaleur:Etude de L'evolution d'une alite hydrate dans la gamme de temperature 20-400℃,Materiaux et Construction,1(1968):365-378.
  • 10Frederic Skoezylas.Sur la fiabilite des measures des permeabilites heterogenes par injection de gas.Micropulse tests,Revue francaise de genie eivi.Volume 7-n°4/2003:451-469.