期刊文献+

微滤膜法预处理周位酸有机废水

Pretreatment of Peri Acid Organic Wastewater by Microfiltration Membrane
下载PDF
导出
摘要 采用微滤膜预处理周位酸有机废水,探讨了废水pH值、操作压力、操作温度对微滤膜预处理效果的影响。结果表明,在废水pH值为10、操作压力为0.1 MPa、操作温度为室温的条件下,废水COD截留率达58%,色度明显减小,微滤膜片经机械清扫和反水冲洗后可恢复部分膜通量。为微滤膜法预处理周位酸有机废水的工业化提供了基础数据和理论依据。 Peri acid organic wastewater was pretreated by microfiltration membrane.The effects of pH value of wastewater,operation pressure,operation temperature on pretreatment efficiency were investigated.Results showed that,the retention rate of COD was 58%,chroma decreased obviously under optimum conditions as follows:pH value of wastewater of 10,operation pressure of 0.1 MPa,operation temperature of room temperature.Through mechanical cleaning and anti-water flushing,the partly membrane flux of used microfiltration membrane restored.This research provides basic data and theoretical evidence for industrialization of pretreatment of peri acid organic wastewater by microfiltration membrane.
出处 《化学与生物工程》 CAS 2015年第3期33-35,共3页 Chemistry & Bioengineering
基金 国家自然科学基金资助项目(51346005) 武汉工程大学第九期大学生校长基金资助项目(2014001)
关键词 微滤膜 预处理 膜通量 截留率 microfiltration membrane pretreatment membrane flux retention rate