期刊文献+

流式细胞术操作软件在小鼠造血干细胞检测中的应用比较 被引量:3

Comparison of kinds of flow cytometry operation software in mice bone marrow hematopoietic stem cell analysis
下载PDF
导出
摘要 目的 :探讨流式细胞术中不同分析软件在小鼠造血干细胞分析中的特点和差异。方法 :使用小鼠骨髓细胞悬液作为实验材料,在BD Aria III和BD Influx流式细胞仪上检测小鼠造血干细胞,分别应用FACSDiva、FACSSortware软件对检测数据进行分析,并比较分析结果。结果:FACSDiva和FACSSortware软件在参数调节、补偿调节、圈门、数据保存和分选设置方面存在细微差异,均可以实现多色流式分析和高速流式分选。结论:FACSDiva和FACSSortware软件分析同一样本所得结果有较高的一致性,均是使用流式细胞仪不可或缺的工具。 Objective To explore the characteristics and differences of kinds of flow cytometry operation software for mice bone marrow hematopoietic stem cell analysis. Methods With mice bone marrow cells as experimental materials, cells were stained by antibodies and measured by BD Aria III and BD Influx flow cytometer. The results of hematopoietic stem cell were analyzed and compared by FACSDiva and FACSSortware software. Results Discrepancies of FACSDiva and FACSSortware involved parameter regulation, compensation regulation, gating, data storage and sorting parameter setting.Both of the softwares were effective to complete multicolor flow analysis and high-speed cell sorting. Conclusion Results of the same sample analyzed by FACSDiva and FACSSortware can obtain high consistency.
出处 《医疗卫生装备》 CAS 2015年第3期5-8,共4页 Chinese Medical Equipment Journal
基金 国家自然科学基金资助项目(81001377)
关键词 流式细胞术 造血干细胞 FACSDiva软件 FACSSortware软件 flow cytometry hematopoietic stem cell FACSDiva software FACSSortware software
  • 相关文献

参考文献14

  • 1张燕,白雪芹,邓飞(审校).小鼠造血干细胞表型的研究进展[J].医学信息,2013(8):701-701. 被引量:2
  • 2Osawa M, Hanada K, Hamada H,et al. Long-term lymphohematopoi- eric reconstitution by a single CD34-1ow/negative hematopoietic stem cell[J]. Science, 1996,273 (5 272) :242-245.
  • 3CHEN J, Ellison F M, Keyvanfar K, et ol. Enrichment of hematopoi- eric stem ceils with SLAM and LSK markers for the detection of hematopoietic stem cell function in normal and Trp53 null mice[J]. Experimental Hematology,2008,36(10) :1 236-1 243.
  • 4Simpson C,Pearce D J, Bonnet D,et ol. Out of the blue :a comparison of Hoechst side population (SP) analysis of murine bone marrow us- ing 325,363 and 407 nm excitation sources[J]. Jou'rnal of Immuno- Logical Methods,2006,310( 1 ) : 171-181.
  • 5Spangrude G J, Heimfeld S, Weissman I L. Purification and charac- terization of mouse hematopoietic stem cells[J]. Science, 1988,241 (4 861 ) :58-62.
  • 6Goodell M A, Rosenzweig M, Kim H,et d. Dye efflux studies suggest that hematopoietic stem cells expressing low or undetectable levels of CD34 antigen exist in multiple species[J]. Nature Medicine, 1997, 3(12):1 337-1 345.
  • 7Lin K K, Goodell M A. Purification of hematopoietie stem cells using the side population[J]. Methods in Enzymology, 2006,420: 255-264.
  • 8Morita Y, Ema H, Yamazaki S, et al. Non-side-population hemato - poietic stem cells in mouse bone marrow[J]. Blood, 2006,108 (8) : 2 850-2 856.
  • 9Telford W G,Frolova E G. Discrimination of the Hoeehst side popu- lation in mouse bone marrow with violet and near-ultraviolet laser diodes[J]. Cytometry Part A, 2004,57 ( 1 ) :45-52.
  • 10曹云新,胡金涛,杨安钢.FACS-Aria流式细胞分选调试参数和最佳条件的设定[J].第四军医大学学报,2007,28(19):1813-1815. 被引量:17

二级参考文献62

共引文献60

同被引文献6

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部