期刊文献+

Novel FGMOS Based PCS Device for Low Power Applications

Novel FGMOS Based PCS Device for Low Power Applications
原文传递
导出
摘要 The spice model for photo catalytic sensor (PCS) proposed by Whig and Ahmad overcomes several drawbacks like complex designing, non-linearity, and long computation time generally found in the flow injection analysis (FIA) technique by Yoon-Chang Kim et al. for the determination of chemical oxygen demand (COD). The FIA technique involves the complete analysis including sampling and washing. The flow injection analysis is an analytical method for the measurement of the chemical oxygen demand by using the photochemical column. This method uses a bulky setup and takes 10 minutes to 15 minutes to get the output result which is a tedious and time consuming job. If the conventional method is continuously used for a long time then it is stable only for 15 days. The purpose of this paper is to propose a new floating gate photo catalytic sensor (FGPCS) approach which has low power consumption and more user-friendly, and it is fast in operation by the modeling and optimization of sensor used for water quality monitoring. The proposed model operates under sub-threshold conditions which are appreciated in large integrated system design. The results of simulation are found to be fairly in agreement with the theoretical predictions. The results exhibit near linear variations of parameters of interest with appreciably reduced response time. The spice model for photo catalytic sensor (PCS) proposed by Whig and Ahmad overcomes several drawbacks like complex designing, non-linearity, and long computation time generally found in the flow injection analysis (FIA) technique by Yoon-Chang Kim et al. for the determination of chemical oxygen demand (COD). The FIA technique involves the complete analysis including sampling and washing. The flow injection analysis is an analytical method for the measurement of the chemical oxygen demand by using the photochemical column. This method uses a bulky setup and takes 10 minutes to 15 minutes to get the output result which is a tedious and time consuming job. If the conventional method is continuously used for a long time then it is stable only for 15 days. The purpose of this paper is to propose a new floating gate photo catalytic sensor (FGPCS) approach which has low power consumption and more user-friendly, and it is fast in operation by the modeling and optimization of sensor used for water quality monitoring. The proposed model operates under sub-threshold conditions which are appreciated in large integrated system design. The results of simulation are found to be fairly in agreement with the theoretical predictions. The results exhibit near linear variations of parameters of interest with appreciably reduced response time.
出处 《Photonic Sensors》 SCIE EI CAS CSCD 2015年第2期123-127,共5页 光子传感器(英文版)
关键词 FGPCS spice modeling SIMULATION photo catalytic sensor flow injection analysis macro model FGPCS, spice modeling, simulation, photo catalytic sensor, flow injection analysis, macro model
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部