摘要
目的:探讨并建立两性霉素B阴道泡腾片微生物限度检查方法。方法:采用薄膜过滤-培养基稀释法,用6株阳性试验菌验证其抑菌性是否消除。结果:所建方法回收率≥70.0%,并且3株阳性试验菌检出率为100%。结论:采用本文探讨的方法消除该药品的抑菌作用是有效的,该法适用于两性霉素B阴道泡腾片的微生物限度检查。
Objective: To discuss and construct a microbial limit test method of Amphotericin B Vaginal Effervescent Tablets. Method:Adopting membrane filtration and culture medium dilution methods to test whether the bacteriostatic effect was eliminated using six positive test strains. Result: The recovery rate was greater than 70% and the positive rate of three positive test strains was 100% o Conclusion: It is effective that using the method discussed in this paper to eliminate the hacteriostatic action , it can be used as microbial limit test for Amphotericin B Vaginal Effervescent Tablets.
出处
《中国药品标准》
CAS
2015年第1期27-30,共4页
Drug Standards of China
关键词
两性霉素B阴道泡腾片
微生物限度检查
回收率
Amphotericin B Vaginal Effervescent Tablets
microbial limit test
recovery rate