摘要 通过对直接空冷传统抽汽供热热电联产机组及热网供回水温度存在的问题进行分析,提出了抽汽-乏汽联合供热系统,并经全面性能耗计算分析了抽汽-乏汽供热与传统抽汽供热的经济性。通过技术改造后数据得出,抽汽-乏汽供热系统较抽汽供热方式节约发电煤耗约26 g/k Wh、发电机功率可增加20.36 MW、可增加供热面积约70万m2,有很大的节能潜力。 In this paper, through the analysis on the existing problems of heat extraction of direct air-cooling combined heat and power units and water supply and return temperatures of the heat-supply network, a combined extraction and exhaust steam heating system is proposed and the economic comparison between the proposed and the original systems is performed based on the calculation of overall energy consumption. The result exhibits that in the combined extraction and exhaust steam heating system, the coal consumption is decreased by 26 g/kWh, the generator power is increased by 20.36 MW, and 700 thousand m2 more of heating area is increased, suggesting great energy saving potentials.
出处 《中国电力》 CSCD 北大核心 2015年第3期17-20,共4页 Electric Power
关键词 热电联产 抽汽供热 乏汽供热 combined heat and power extraction heating exhausted steam heating