婴儿培养箱温湿度无线测量网络的开发与应用 被引量:8

Development and Application of a Wireless Temperature and Humidity Monitoring Network System for Infant Incubators
下载PDF
导出
摘要 基于物联网RFID技术开发婴儿培养箱温湿度集中监测系统,实时将监测到的婴儿培养箱温湿度数据传输到主机,进行存储、分析,对设备发生的异常现象,以多媒体语音等多种形式报警。本系统的应用,提高了婴儿医疗的安全性和工作效率,减少了不良事件的发生。 A wireless temperature and humidity monitoring network system was developed by the hospital based on the RFID(Radio Frequency Identification) technology in the field of Io T(Internet of Things),which was intended for monitoring temperature and humidity of the infant incubator and realtimely transferring the relevant data to the mainframe computer for storage and analysis.Audible and visual warnings would be activated in multiple approaches in case of malfunctioned infant incubators.As a consequence,application of the system has enhanced the security and efficiency of medical services for infants and lowered the occurrence of medical adverse events.
作者 姚新琴 解兵
出处 《中国医疗设备》 2015年第3期83-85,共3页 China Medical Devices
基金 浙江省卫计委科技计划项目(2013ZHA016) 绍兴市科技计划项目(2013D10037)
关键词 婴儿培养箱 无线测量网络 温湿度监测系统 传感器 infant incubator wireless monitoring network system temperature and humidity monitoring system sensor
  • 相关文献

参考文献7

二级参考文献13

  • 1..HTTP://www. sensirion. com/en/pdf/Datasheet-SHT1x-SHT7x.pdf,.
  • 2何立民.I^2C总线应用设计[M].北京:航空航天大学出版社,..
  • 3Anitesh Barua,et al.Assessing the Financial Impacts of RFID Technologies on the Retail and Healthcare Sectors[EB/OL]. (2006-02-13). [2009-12-29] .http://www.rfidsolutionsonline. com/download.mvc/Assessing-The- Financial-lmpacts-Of- RFID-Techn-0001?VNETCOOKIE=NO.
  • 4Ekahau.Emergin and Ekahau Partnership to Deliver Wireless Notifications Triggered by Location-Awareness; Healthcare Facilities Benefit From Combined Power of Emergin's Zero-Defect Communication Platform and Ekahau's RealTime Location System[EB/OL].( 2006-5-16).[2009-12- 29] .http://www.directionsmag.com/press.releases/index. php?duty=Show&id=14312&try= 1.
  • 5Alan Greenspan. Business Action to Stop Counterfeiting and Piracy[R/OL].USCIB. (2004-02-17). [2009-12-29].http:// www.uscib.org/docs/BASCAP_factsheet.pdf.
  • 6Medicom. Facts and figures on non compliance[R./OL]. Medicom. Bang-Olufsen.(2005-05-23).[2009-12-29].http://www. medicom.bang-olufsen.com/sw 1359.asp.
  • 7Gavin Chappell,Lyle Ginsburg, Paul Schmidt, et al. The Value of Auto-ID Technology in Consumer Packaged Goods Demand Planning[EB/OL]. (2002-11-01).[2009-12-29]. http://www. accture.com/Silent Commerce, 2003, 2.
  • 8CJ Towner, S Zujkowski.Economic Benefits of EPC in Pharmaceuticals[R].Capgemini Life Sciences, 2004.
  • 9Binnekade JM, Bakker PJM.Electromagnetic Interference From Radio Frequency Identification Inducing Potentially Hazardous Incidents in Critical Care Medical Equipment[J]. JAMA,2008,299(24):2884-2890.
  • 10Sensirion公司.SHT11数据手册[M].,2003..

共引文献157

同被引文献84

引证文献8

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部