期刊文献+

磁共振相位对比法电影成像技术在脑脊液测速中的初步研究

Preliminary study of cine phase contrast imaging on CSF flow measurement
下载PDF
导出
摘要 目的探讨小角度快速激发扰相位梯度回波序列相位对比法电影成像技术在脑脊液测速中的应用价值。方法采用德国Siemens Avanto 1.5T超导磁共振扫描仪,对16例健康志愿者先行头颅MRI检查,再行(Cine phase contrast,Cine PC)相位对比法电影成像技术结合使用外周的指脉或心电门控等技术并应用Argus软件进行数据测量及分析,在横轴位图像上勾画出ROI(感兴趣区),测量中脑导水管在一个心动周期内脑脊液流动的各动力学参数值。结果 16例健康人的MRI PC幅值图均清晰显示测量区域的解剖结构,定位准确;相位图(phase image)均可判断脑脊液流动的方向、流速的快慢、信号的强弱,并能应用Argus软件进行数据测量及分析。结论相位对比法电影成像技术结合心电同步采集技术,具有成像速度快、突出T1WI加权、电影成像的特点,可以作为脑脊液测速的常规扫描技术。 Objective To investigate the application value of Cine phase contrast (Cine PC) imaging technique with small angle stimulation on spoiled gradient echo. Methods Performed head MRI examinations for 16 healthy volunteers on the 1.5T Siemens Avanto MRI, and then applied Cine PC imaging technique combined with peripheral pulse or ECG trigger. Analyzed the data with the Argus software, and marked the region of interest (ROI) on the transverse axis of the image to measure the kinetic parameters of cerebrospinal fluid (CSF) flow at aqueduct of sylvius in a cardiac cycle. Results All PC amplitude images from the 16 healthy volunteers' MR/ examinations displayed the exact localization of anatomical structures at the region measured. The direction, velocity and signal strength of CSF flow could all be estimated and analyzed on the phase images by using the Argus software. Conclusions The Cine PC imaging technique combined with ECG synchronous acquisition could be used as general routine for velocity measurement of CSF flow due to the characteristics of fast and Cine imaging as well as outstanding T1WI.
出处 《齐齐哈尔医学院学报》 2015年第6期834-836,共3页 Journal of Qiqihar Medical University
关键词 相位对比法 电影成像技术 磁共振成像 脑脊液测速 Phase contrast (PC) Cine imaging technique MRI Cerebrospinal fluid (CSF) flow measurement
  • 相关文献

参考文献12

二级参考文献113

  • 1朱晓黎,沈天真,陈星荣.正常中脑导水管脑脊液流动磁共振定量研究[J].医学影像学杂志,2004,14(11):875-878. 被引量:19
  • 2朱晓黎,沈天真,陈星荣.MR相位对比电影法在正常颈部及颅内大血管血流测量中的应用[J].中国医学影像技术,2005,21(3):365-368. 被引量:17
  • 3[1]Feinberg DA, Mark AS. Huaman brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging. Radiology 1987; 163:793 ~ 799
  • 4[3]Bergsrand G, Bergstrom M, Nordell B, et al. Cardiac gated MR imaging of cerebrospinal fluid flow. J Comput Assist Tomogr 1985; 1003 ~ 1006
  • 5[4]Greitz D, Greitz T. The pathogenesis and hemodynamics of hydrocephalus: proposal for a new understanding. IJNR 1997; 3:367 ~ 375
  • 6[5]Greitz D, Wirestan R, Franck A, et al. Pulsatile brain movement and associated hydrodynamics studied by magnetic resonance phase imaging. Neuroradiology 1992; 34:370 ~ 380
  • 7[6]Bradeley WG, Whittemore AR, Kortman KE, et al. Marked cerebrospinal fluid void. Indicator of successful shunt in patients with suspected normal pressuure hydrocephalus. Radiology 1991; 178:459 ~ 467
  • 8[7]Mascalchi M, Ciraolo L, Bucciolini M, et al. Fast multiphase MR imaging of aqueductal CSF flow: study in patients with hydrocephalus. AJNR 1990; 11: 597 ~ 603
  • 9[8]Nitz RG, Bradeley WG, Watanabe AS, et al. Flow dynamics of cerebrospinal fluid:assessment with phase - contrast velocity MR imaging performed with retrospective cardiac gating. Radiology 1992; 183:395 ~ 405
  • 10[9]Gideon P, Stahlberg F, Thomsen C, et al. Cerebrospinal fluid and production in patients with normal pressure hydrocephalus studied by MRI. Neuroradiology 1994; 36:210 ~ 215

共引文献256