表面肌电图在脑卒中患者手神经肌肉功能评定中的应用 被引量:38

Evaluating Hand Neural-muscle Function after Stroke with Surface Electromyography(review)
下载PDF
导出
摘要 表面肌电图(s EMG)作为一种客观定量的评估工具,近年来已逐渐应用于脑卒中后手神经肌肉功能障碍的康复评定。本文综述近10年的相关文献,主要介绍s EMG分析手神经肌肉功能的常用参数,以及s EMG在脑卒中患者手神经肌肉功能障碍评定中的应用。 Surface electromyography(s EMG), as an objective and quantitive assessment tool, has been used to evaluate the hand neural- muscle dysfunction after stroke in recent years. This paper reviews related literatures in nearly 10 years, which mainly introduced the common parameters of s EMG for the hand neural-muscle function, focused on the application of s EMG to estimate hand neural-muscle dysfunction after stroke.
出处 《中国康复理论与实践》 CSCD 北大核心 2015年第3期280-283,共4页 Chinese Journal of Rehabilitation Theory and Practice
基金 上海市卫生计生委重大推广类项目(No.2013SY002) 上海市科委重大项目-2013年度"科技创新行动计划"(No.13411951101)
关键词 表面肌电图 脑卒中 神经肌肉 评定 综述 surface electromyography stroke hand neural-muscle assessment review
  • 相关文献

参考文献36

  • 1Park K, Kwon S, Kim J, et al. Bimanual shoulder flexion sys- tem with surface electromyography for hemiplegic patients af- ter stroke: A preliminary study [J]. IEEE Int Conf Rehabil Ro- bot, 2011, 2011: 597-588.
  • 2Hu XL, Tong KY, Wei XJ, et al. The effects of post-stroke up- per- limb training with an electromyography (EMG)-driven hand robot [J]. J Electromyogr Kinesiol, 2013, 23(5): 1065-1074.
  • 3Theilig S, Podubecka J, B6sl K, et al. Functional neuromuscu- lar stimulation to improve severe hand dysfunction after stroke: Does inhibitory rTMS enhance therapeutic efficien- cy? [J]. Exp Neurol, 2011,230(1): 149-155.
  • 4Knutson JS, Chae J, Hart RL, et al. Implanted neuroprosthesis for assisting arm and hand function after stroke: a case study [J]. J Rehabil Res Dev, 2012, 49(10): 1505-1516.
  • 5郑洁皎,胡佑红,俞卓伟.表面肌电图在神经肌肉功能评定中的应用[J].中国康复理论与实践,2007,13(8):741-742. 被引量:71
  • 6Meekins GD, So Y, Quan D. American Association of Neuro- muscular & Electrodiagnostic Medicine evidenced-based re- view: Use of surface electromyography in the diagnosis and study of neuromuscular disorders [J]. Muscle Nerve, 2008, 38 (4): 1219-1224.
  • 7Disselhorst-Klug C, Schmitz-Rode T, Rau G. Surface electro- myography and muscle force: Limits in sEMG-force relation- ship and new approaches for applications [J]. Clin Biomech, 2009, 24(3): 225-235.
  • 8Malone A, Meldrum D, Gleeson J, et al. Reliability of surface electromyography timing parameters in gait in cervical spondy- lotic myelopathy [J]. J Electromyogr Kinesiol, 2011, 21(6): 1004-1010.
  • 9Watanabe K, Akima H. Validity of surface electromyography for vastus intermedius muscle assessed by needle electromyog- raphy [J]. J Neurosci Methods, 2011, 198(2): 332-335.
  • 10Hashemi OA, Paulin MG, Carman AB. Intra-session and in- ter-day reliability of forearm surface EMG during varying hand grip forces [J]. J Electromyogr Kinesiol, 2013, 23(1): 216-222.

二级参考文献66

共引文献92

同被引文献435

引证文献38

二级引证文献418