期刊文献+

电力变压器绝缘纸板绝缘寿命面临的挑战 被引量:5

Lifetime Challenges for the Insulating Pressboard of Power Transformer
下载PDF
导出
摘要 变压器是电力系统的核心设备,电力变压器的寿命主要取决于变压器内绝缘纸板的寿命,绝缘纸板在变压器内长时间使用会加速纸板纤维的老化,影响纸板的电气和机械性能,从而降低其使用寿命。随着电网向特高压大容量方向发展,对电力变压器绝缘纸板的质量要求更高。本文概述了绝缘纸板绝缘老化特性和绝缘寿命面临的挑战和解决的方向,期待这方面的研究将得到更广泛的关注。 Power transformers are key elements in power systems. A power transformer lifetime is typically defined by the lifetime of the insulating cellulose pressboard in the transformer.The insulating cellulose pressboard will age in service and influence its electrical and mechanical performances, which decrease its service lifetime. As the power network orients in 'extra-high voltage, large capacity', that makes the requirement of performance of the insulating pressboard more strictly. We provide the challenges on improving the insulating pressboard anti-aging characteristic and thus extending its service lifetime,and believe that the research and development in the area of insulating pressboard will surely create many fruitful results.
出处 《湖南造纸》 2015年第1期17-19,共3页 Hunan Papermaking
关键词 绝缘纸板 电力变压器 绝缘老化 绝缘寿命 挑战 Insulating pressboard,power transformer,insulating aging,insulating lifetime,challenge
  • 相关文献

参考文献9

  • 1Prevost T., Oommen T. Cellulose insulation in oil filled power transformers: Part I - history and development [J]. IEEE Electrical Insulation Magazine, 2006, 22(1):28-35.
  • 2Lundgaard E.,Hansen W.,Linhjell D., Painter J. Aging of oil-impregnated paper in power transformers [J]. IEEE Transactions on Power Delivery, 2004, 19(1):230-239.
  • 3吕健,詹怀宇,晋华春.电力变压器绝缘纸的性能及其绝缘老化[J].中国造纸,2008,27(5):54-58. 被引量:38
  • 4Gilbert R., Jalbert J., T & treault P., Morin B., Denos Y. Kinet- ics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil sys- tems. Part 1: Standard wood kraft insulation [J]. Cellulose, 2009, 16 (2): 327-338.
  • 5Baird J., Herman H., Stevens C., Jarman N. Spectroscopic measurement and analysis of water and oil in transformer insulating paper [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2006, 13(2):293-308.
  • 6陈启杰.一种变压器绝缘纸用抗老化剂的制备方法[P].中国专利:2013101993854.
  • 7廖瑞金,梁帅伟,杨丽君,王红梅,孙才新,孙会刚.天然酯-普通纸(或热稳定纸)绝缘热老化特性[J].电工技术学报,2009,24(12):12-17. 被引量:15
  • 8肖鹏远,焦晓宁.绝缘纸的性能及Nomex绝缘纸的特性和应用[J].产业用纺织品,2010,28(1):31-36. 被引量:26
  • 9廖瑞金,唐超,杨丽君,孙才新,张昀.电力变压器用绝缘纸热老化的微观结构及形貌研究[J].中国电机工程学报,2007,27(33):59-64. 被引量:41