期刊文献+

动力空压站UPS不间断供电系统升级改造 被引量:2

UPGRADE REVAMP ON UNINTERRUPTED POWER SUPPLY SYSTEM OF AIR PRESSURE POWER STATION
下载PDF
导出
摘要 针对动力空压站UPS系统设备超期服役、元器件老化、安装地点不适宜、系统电源配置不合理等现状,重点从设备选型、变更安装地点、优化系统配置方面进行升级改造。项目实施后,实现了高效、稳定运行。 Aimed at current situations of overtime service,aging of components and parts,unsuitable installation site and unreasonable electrical source formulation existing in uninterrupted power supply( UPS) system of the air pressure power station,revamps involving equipment selection,alteration of the installation site and optimization on system formulation were mainly executed. High efficiency and stable running of the uninterrupted power supply system was realized after the upgrade revamp.
作者 耿新军
出处 《齐鲁石油化工》 2015年第1期40-42,共3页 Qilu Petrochemical Technology
关键词 UPS 原理 选型 优化配置 管理 维护 UPS principle model selection optimization on formulation management maintenance