期刊文献+

油田集输用玻璃钢管接头处开裂分析 被引量:6

Failure Analysis of Glass Fiber Reinforced Pipe for Oil Gathering Pipeline
下载PDF
导出
摘要 集油管线用玻璃钢管在使用过程中发生了管体脆性开裂失效事故。为了探讨玻璃钢管的失效原因,采用差式扫描量热仪、水压试验机、材料试验机等分析手段,研究了玻璃钢管的失效断口形貌、玻璃化转变温度、树脂含量、承压能力和管体与接头位置力学性能等。结果表明:玻璃钢管树脂含量偏低导致树脂对纤维胶合作用降低,是玻璃钢管力学性能较低、容易失效的重要原因。玻璃钢管端部刚度不及管体部位1/2,在受到外部地层沉降或其它外力载荷条件下,管端部位出现脆性开裂而导致漏油。 A GFRP for oil gathering pipeline failed during service. Investigations were performed to identify the possible failure causes of the pipe. The failure fracture morphology, Tg, resin content, hydraulie pressure rating, outer" load resisting perfnrmanee of tire pipe and the joint position were systematically studied by using DSC, hydraulic pressure testing machine and MTS, etc. The resuhs showed that lower resin content lead to the lower bonding effect of resin on the fiher, which is an important cause of lower mechanical property of GFRP and easy to failure. The sliffness of pipe near the joint is less than half of that the pipe body. The pipe near the joint end occurred brittle cracking and lead to oil spills under the ground settlement or other external loading conditions,
出处 《石油管材与仪器》 2015年第1期43-46,共4页 Petroleum Tubular Goods & Instruments
关键词 玻璃钢管 失效分析 树脂含量 端部刚度 glass fiber reinforeed pipe, failure analysis, resin content, stiffness of pipe near joint
  • 相关文献

参考文献4

  • 1同家发展和改革委员会.高压玻璃纤维管线管和管件[S].SY/T6267,2006.
  • 2同家能源局.非金属管材质量验收规范第1部分:高压玻璃纤维管线管[S].SY/T6770.1,2010.
  • 3冈家发展和改革委员会.低压玻璃纤维管线管和管件[S].SY/T6266,2004.
  • 4中华人民共和围困家质量监督检验检疫总局.纤维增强热同性塑料管平行板外载性能试验方法[s].GB/T5352,2005.