为了解决唐山地区调度数据网存在的220 kV与110 kV变电站的IP地址使用混乱、OSPF区域划分不合理、设备双上联未完全覆盖、核心汇聚层带宽不足等问题,文章以降低路由器运行压力,提高设备运行稳定性,提高调度数据通道的运行率为目的,通过IP地址调整和连接方式改变对网络进行优化,减少了通道中断时间和对承载业务的影响。
To solve the problems such as nonstandard use of IP addresses of 220 kV and 110 kV substations, unreasonable division of OSPF, incomplete equipment dual-connection cover and insufficient bandwidthof core convergence layer inTangshan dispatching data network,by adjusting IP addresses and changing connection modes, the network is optimized to reduce the operation pressure of router, improve the reliability of equipment operationand the availability of data channel. The results show that channel interrupt time and impacts on the bearer service are redticed.