摘要 病例女,65岁,6年前因右冠状动脉斑块并重度狭窄行右冠状动脉支架植入术,选用雷帕霉素洗脱支架2枚(3.5 mm×33 mm),中间部分重叠植入。近2月来每于苏醒及激动时出现胸闷、憋气,无胸痛,无恶心呕吐,服用硝酸甘油缓解,持续时间10余分钟,症状反复发作。查体:心前区无隆起,未触及震颤,心尖搏动不弥散,心界不大,心率58次/min,律整,心音可,可闻及心尖部收缩期杂音,无心包摩擦音及心包叩击音,周围血管征阴性。
出处 《中国临床医学影像杂志》 CAS 北大核心 2015年第3期225-226,共2页 Journal of China Clinic Medical Imaging
  • 相关文献

参考文献5

  • 1Aoki J, Nakazawa G, Tanabe K, et al. Incidence and clinical im- pact of coronary stent fracture after sirolimus-eluting stent im- plantation[J]. Catheter Cardiovasc Intervent, 2007, 69(3): 380-386.
  • 2赵继义,李悦,李为民.冠状动脉支架断裂研究进展[J].中国循环杂志,2008,23(3):234-236. 被引量:3
  • 3Popma J]. Stent fractures after DES: definitions, frequency, tim- ing, device specificity, and associated clinical events transcatheter cardiovascular therapeutics(TCT)[M]. Washington DC: Attendee In- teractive LCC, 2008: 452-455.
  • 4Doi H, Maehara A, Mintz GS. Classification and potential mecha- nisms of intravascular 'ultrasound patterns of stent fracture[J]. Am J Cardial, 2009, 103(6): 818-823.
  • 5Nakazawa G, Finn AV, Vorpahl M, et al. Incidence and predic- tors of drug-eluting stent fracture in human coronary artery: a pathologic analysis [J]. J Am Coll Cardiol, 2009, 54 (21): 1924- 1931.

二级参考文献26

  • 1Shite J,Matsumoto D,Yokoyama M.Sirolimus-elufing stem fracture with thrombus,visualization by optical coherence tomngraphy.Eur Heart J,2006,27:i389.
  • 2Kim EJ,Rha SW,Wani SP,et al.Coronary stont fracture and restenosis in the drng-eluting stent era:do we have clues of management? Int J Cardiol,2007,120:417-419.
  • 3Surmely JF,Kinoshita Y,Dash D,et al.Stent strut fracture-induced restenosis in a bifurcation lesion treated with the crush atenting technique.Circ J,2006,70:936-938.
  • 4Koh TW,Mathur A.Coronary stent fracture in a saphanous vein graft to right coronary artery-suocessful treatment by the novel use of the Joined coronary stent graft:case report and review of the literature.Int J Cardiol,2007,119:e43-e45.
  • 5Min PK,Ycon YW,Moon Kwon H.Delayed strut fraeture of sirolimus-eluting stent:a significant problem or an occasional observation? Int J Cardiol,2006,106:404-406.
  • 6Mehrle A,Skelton T,Almonacid A.Stent fracture:an unusual cause of late restenosis after sirolimus-eluting stent placement.Catheter Cardiovasc Interv,2007,69:989-992.
  • 7Jin X,Zhang S,Xie H,et al.Strut fracture of DES:an increasing problem? Im J Cardiol,2007,118:e54-e56.
  • 8Brilakis ES,Maniu C,Wahl M,et al.Unstable angina due to stent fracture.J Invasive Cardiol,2004,16:545.
  • 9Makaryus AN,Lefkowitz L,Lee AD.Coronary artery stent fracture.Int J Cardiovasc Imaging,2007,23:305-309.
  • 10Vaknin-Assa H,Assali A,Fuehs S,et al.An unusual cluster of complications following drog-eluted stenting:stent fracture,peristent aneurysm and late thromboeis.Isr Med Assoc J,2007,9:331-332.

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部