摘要
结合环境监测实际工作,对GB/T7467—1987二苯碳酰二肼分光光度法测定水中六价铬的方法进行了适当的改进,在配制二苯碳酰二肼显色剂时,以乙醇代替有毒的丙酮作为溶剂,同时加入适量硫酸和磷酸,配成含混合酸的显色剂,分析时一次加入,简化操作步骤,提高了工作效率;对含色度、浊度的水样前处理方法进行了优化。改进方法与国标法测定结果无显著性差异,实际样品加标回收率在91%-110%之间,能够确保水样六价铬测定的精密度和准确度。
Combined with the work practice of environmental monitoring, the method for determi- nation of chromium ( Ⅵ ) by 1, 5-diphenylcarbohydrazide spectrophotometry ( GB/T 7467 - 1987 ) in water and wastewater was improved. The diphenylcarbohydrazide chromogenic agent was prepared by u- sing ethanol instead of toxic acetone as the solvent, adding appropriate amount of sulfuric acid and phos- phoric acid at the same time. When analyzing, the chromogenic agent containing mixed acid was added once, simplifying procedures and improving work efficiency. The pre-treatment method of water samples containing color and turbidity was optimized. The improved method has no significant difference in the re- suits compared with the national method, and the recovery of the actual samples was 91% to 110%, which could ensure the precision and accuracy in determination of chromium (V[) in water samples.
出处
《中国给水排水》
CAS
CSCD
北大核心
2015年第8期106-108,共3页
China Water & Wastewater
关键词
六价铬
二苯碳酰二肼
色度校正
chromium (Ⅵ)
1, 5-diphenylcarbazide
color correction