期刊文献+

660MW超超临界锅炉NO_x排放特性试验研究 被引量:6

Experimental Study on a 660MW Ultra-supercritical Boiler NO_x Emission
下载PDF
导出
摘要 通过对某电厂660MW超超临界锅炉的研究,在改变锅炉负荷、运行氧量、SOFA风量和配风方式等情况下,测定锅炉脱硝入口处NOx排放浓度,分析燃烧调整对NOx排放的影响。通过研究表明:在额定负荷运行时,氧量3.0%时,NOx排放最低;中负荷500MW运行时,氧量3.3%时,NOx排放最低。燃烧试验煤种时,当煤粉细度R90降低到25%时,NOx排放降低了4.2%;降低一次风量可以使NOx的排放降低;在额定负荷下,缩腰型配风方式NOx排放最低。 By studying the 660MW ultra supercritical boiler, this paper measures NOx emission concentration at the entrance of boiler denitration, analyzes the effects of combustion adjustment to the NOx emissions with various of boiler load, coefficient of excess air, sofa air and air distribution.The results demonstrate that NOx emissions are minimum under rated load and coefficient of excess air is 3 %.When boiler load turning into 500MW and coeffi-cient of excess air is 3.3%, NOx emissions is the least.According to combustion test of coal, NOx emissions de-cline when R90 is 25%, NOx emissions reduce by 4.2%.The emissions is the least with waist drum air distribution at the rated load.
出处 《电力科学与工程》 2015年第3期18-22,共5页 Electric Power Science and Engineering
关键词 超超临界 运行氧量 NOX排放 一次风量 ultra-supercritical operation oxygen NOx emissions primary air volume
  • 相关文献

参考文献12

二级参考文献105

共引文献332

同被引文献38

引证文献6

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部