讲述了集散控制系统(DCS)与第三方通讯的必要性,并以霍尼韦尔PKS与第三方设备通讯组态为例,介绍了硬件配置及软件组态的具体方法,着重介绍了霍尼韦尔PKS侧的组态,最终实现第三方数据在PKS操作站中正确显示。
The necessity of the communication between distributed control system(DCS) and third-party was described. Taking the configuration of the communication between Honeywell PKS and third-party as an example, specific methods of the hardware configuration and software configuration were introduced, the configuration of Honeywell's PKS side was especially discussed to correctly display third-party data in PKS's station.