摘要 IEC 61850标准是当前变电站自动化系统通信的研究热点。研究了IEC 61850信息建模技术和避雷器监测IED建模步骤,分析了其所必要的通信服务。在研究IEC 61850信息模型内涵的基础上,并针对避雷器在线监测的特点,研究扩展和使用了IEC 61850标准中的逻辑节点和数据,对实际避雷器监测IED进行了建模,探究了IEC 61850标准的抽象通信服务接口、特定通信服务映射等通信关键技术。简单介绍了用于装置自我描述的变电站配置语言(SCL),通过SCL对监测模型进行了描述,实现了其工程化的配置。 IEC 61850 standard is the current hot topic of substation automation system communication.In this paper,IEC 61850 information modeling techniques and modeling steps of arrester monitoring IED,analyze the communications services they need to.On the basis of researching the intension of IEC 61850 information model and in the light of the characteristics of arrester online monitoring,logical nodes and data in the IEC 61850 standard are rationally developed and applied.The paper studies communication key technologies of IEC 61850 standard,such as abstract communication service interface (ACSI),specific communication service mapping (SCSM),etc.Finally,the configuration file for the self-description of devices by Substation Configuration description Language(SCL) is briefly introduced.The model for actual intelligent electronic device(IED) of arrester monitoring is established and described in SCL,and realized engineering configuration.
出处 《电子测量技术》 2015年第3期124-128,共5页 Electronic Measurement Technology
关键词 IEC 61850 信息建模技术 智能电子设备(IED) 逻辑节点 变电站配置语言(SCL) IEC 61850 information modeling techniques intelligent electronic device logical nodes substation configuration description language
  • 相关文献

参考文献10

二级参考文献98

共引文献264

同被引文献29

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部