期刊文献+

Wavelet-Based Hybrid Thresholding Method for Ultrasonic Liver Image Denoising 被引量:1

Wavelet-Based Hybrid Thresholding Method for Ultrasonic Liver Image Denoising
原文传递
导出
摘要 This paper presents a wavelet-based hybrid threshold method according to the soft- and hard-threshold functions proposed by Donoho. The wavelet-based hybrid threshold method may help doctors to know more details on the liver disease through denoising the ultrasound image of the liver. First of all, an analytical expression for the hybrid threshold function is discussed. The wavelet-based hybrid threshold method is then investigated for ultrasound image of the liver. Finally, we test the influence of this parameter on the proposed method with the real ultrasound image corrupted by speckle noise with different variances. Moreover, we compare the proposed method under the varying parameters with the soft-threshold function and the hard-threshold function. Three metrics, which are correlation coefficient, edge preservation index and structural similarity index, are measured to quantify the denoised results of ultrasound liver image. Experimental results demonstrate the potential of the proposed method for ultrasound liver image denosing. This paper presents a wavelet-based hybrid threshold method according to the soft- and hard-threshold functions proposed by Donoho. The wavelet-based hybrid threshold method may help doctors to know more details on the liver disease through denoising the ultrasound image of the liver. First of all, an analytical expression for the hybrid threshold function is discussed. The wavelet-based hybrid threshold method is then investigated for ultrasound image of the liver. Finally, we test the influence of this parameter on the proposed method with the real ultrasound image corrupted by speckle noise with different variances. Moreover, we compare the proposed method under the varying parameters with the soft-threshold function and the hard-threshold function. Three metrics, which are correlation coefficient, edge preservation index and structural similarity index, are measured to quantify the denoised results of ultrasound liver image. Experimental results demonstrate the potential of the proposed method for ultrasound liver image denosing.
作者 祝海江
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2015年第2期135-142,共8页 上海交通大学学报(英文版)
基金 the Fundamental Research Funds for the Central Universities of China(No.YS1404) the Beijing University of Chemical Technology Interdisciplinary Funds for "Visual Media Computing"
关键词 ultrasonic liver image hybrid threshold function DENOISING wavelet transform ultrasonic liver image,hybrid threshold function,denoising,wavelet transform
  • 相关文献

参考文献30

  • 1Wagner R F, Smith S W, Sandrik J M, et al.Statistics of speckle in ultrasound B-scans [J]. IEEE Transactions on Sonics and Ultrasonics, 1983, 30(3):156-163.
  • 2Insana M F, Wagner R F, Garra B S, et al. Analysis of ultrasound image texture via generalized Rician statistics [J]. Optical Engineering, 1986, 25(6): 743-748.
  • 3Dutt V, Greenleaf J F. ultrasound echo envelope analysis using a homodyned K-distribution signal model [J]. Ultarasonic Imaging, 1994, 16(4): 265-287.
  • 4Jakeman E, Tough R J A. Generalized Kistribution:A statistical model for weak scattering [J].Journal of the Optical Society of America, 1987, 4(9):1764-1772.
  • 5Koo J I, Park S B. Speckle reduction with edge preservation in medical ultrasonic images using a homogeneous region growing mean filter (HRGMF) [J].Ultrasonic Imaging, 1991, 13(3): 211-237.
  • 6Angelova D, Mihaylova L. Contour segmentation in 2D ultrasound medical images with particle filtering[J]. Machine Vision and Applications, 2011, 22(3):551-561.
  • 7Sivakumar R, Nedumaran D. Implementation of wavelet filters for speckle noise reduction in ultrasound medical images: A comparative study [C]//16th International Conference on Signals, Systems and Communication.Chalkida, Greece: IEEE, 2009: 239-242.
  • 8Lan2011a A M L, Andria G, Attivissimo F,et al. Improving B-mode ultrasound medical images [C]// Proceedings of IEEE International Instrumentation and Measurement Technology Conference. Beijing,China: IEEE, 2011: 1704-1708.
  • 9Damodaran N, Ramamurthy S, Velusamy S, et al. Speckle noise reduction in ultrasound biomedical B-scan images using discrete topological derivative [J].Ultrasound in Medicine & Biology, 2012, 38(2): 276-286.
  • 10Sivakumar R, Gayathri M K, Nedumaran D.Speckle filtering of ultrasound B-scan images: A comparative study between spatial and diffusion filters [C]// 2010 IEEE Conference on Open Systems. Kuala Lumpur: IEEE, 2010: 80-85.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部