期刊文献+

An efficient quadrature demodulator for medical ultrasound imaging 被引量:3

An efficient quadrature demodulator for medical ultrasound imaging
原文传递
导出
摘要 Quadrature demodulation is used in medical ultrasound imaging to derive the envelope and instantaneous phase of the received radio-frequency(RF) signal.In quadrature demodulation,RF signal is multiplied with the sine and cosine wave reference signal and then low-pass filtered to produce the base-band complex signal,which has high computational complexity.In this paper,we propose an efficient quadrature demodulation method for B-mode and color flow imaging,in which the RF signal is demodulated by a pair of finite impulse response filters without mixing with the reference signal,to reduce the computational complexity.The proposed method was evaluated with simulation and in vivo experiments.From the simulation results,the proposed quadrature demodulation method produced similar normalized residual sum of squares(NRSS) and velocity profile compared with the conventional quadrature demodulation method.In the in vivo color flow imaging experiments,the time of the demodulation process was 5.66 ms and 3.36 ms,for the conventional method and the proposed method,respectively.These results indicated that the proposed method can maintain the performance of quadrature demodulation while reducing computational complexity. Quadrature demodulation is used in medical ultrasound imaging to derive the envelope and instan- taneous phase of the received radio-frequency (RF) signal. In quadrature demodulation, RF signal is multiplied with the sine and cosine wave reference signal and then low-pass filtered to produce the base-band complex signal, which has high computational complexity. In this paper, we propose an efficient quadrature demodulation method for B-mode and color flow imaging, in which the RF signal is demodulated by a pair of finite impulse response filters without mixing with the reference signal, to reduce the computational complexity. The proposed method was evaluated with simulation and in vivo experiments. From the simulation results, the proposed quadrature demod- ulation method produced similar normalized residual sum of squares (NRSS) and velocity profile compared with the conventional quadrature demodulation method. In the in vivo color flow imaging experiments, the time of the demodulation process was 5.66 ms and 3.36 ms, for the conventional method and the proposed method, respectively. These results indicated that the proposed method can maintain the performance of quadrature demodulation while reducing computational complexity.
出处 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2015年第4期301-310,共10页 信息与电子工程前沿(英文版)
基金 Project supported by the National Key Technology R&D Program of China(No.2011BAI12B02) the Fundamental Research Funds for the Central Universities,China(Nos.2014FZA5019 and 2015FZA5019)
关键词 B型超声成像 彩色血流成像 正交解调 有限冲激响应滤波器 B-mode ultrasound imaging, Color flow imaging, Quadrature demodulation, Finite impulse responsefilter
  • 相关文献

同被引文献11

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部