两级反渗透系统中膜元件的优化组合 被引量:1

Optimal combination of membrane component in first and secondary reverse osmosis system
下载PDF
导出
摘要 明确了二级系统给水p H值约为7.75时系统透盐率达到最低值;论证了对于不同透盐率水平元件,若将较低透盐率元件用于二级系统而较高透盐率元件用于一级系统则全系统透盐率较低;讨论了调换一、二级系统元件的方式即形成系统元件的优化组合,以使全系统产水水质相应提高的工艺措施。 The minimum salt penetration rate could obtain when pH was 7. 75 in secondary system. The components with low penetration rate were used in secondary system and the components with high penetration rate were applied in first system, thus the penetration rate in the whole system was low. The exchange method of first and secondary system components was discussed. In result, the optimal combination of system components was formed, and process measures were adopted in order to improve the water production quality in the whole system.
出处 《供水技术》 2015年第2期1-4,共4页 Water Technology
关键词 反渗透工艺 两级系统 系统透盐率 膜元件组合 reverse osmosis process first and secondary system salt penetration rate ofsystem combination of membrane component
  • 相关文献

参考文献4

二级参考文献7

共引文献32

同被引文献4

引证文献1

二级引证文献7