摘要 目的 探讨LiDCOrapid提供的血流动力学指标能否在剖宫产手术患者中及时、有效地反映缩宫素引起的血流动力学改变.方法 选择美国麻醉医师协会(ASA)分级Ⅰ级,择期剖宫产手术20例,患者入室后应用LiDCOrapid指套、袖带建立无创血压监测(continuous noninvasive arterial blood pressure measurement,CNAP).记录患者入室、胎儿娩出、给予缩宫素后即刻、给药后每间隔10s记录至给药后180 s时患者的血流动力学指标:收缩压(systolic blood pressure,SBP)、舒张压(diastolicblood pressure,DBP)、平均动脉压(mean arterial pressure,MAP)、心率(heart rate,HR)、心排血量(cardiac output,CO)、每搏量(stroke volume,SV).记录患者缩宫素相关副作用.结果 给予缩宫素后,LiDCOrapid记录到患者HR、CO、SV增高,同时SBP、DBP、MAP下降,这与国外应用LiDCOplus建立有创动脉压监测所得血流动力学变化趋势一致.以胎儿娩出时血流动力学指标为基础值,SBP、DBP、MAP、HR、CO、SV均于给药后40 s~60 s达峰,达峰时相对基础值百分比分别为(89±12)%、(73±14)%、(81±12)%、(116±12)%、(174±35)%、(150±27)%,差异有统计学意义(P<0.01).结论 LiDCOrapid与LiDCOplus比较,二者具有一致性,均可及时、有效地反映剖宫产手术中缩宫素引起的快速血流动力学变化.健康产妇给予10单位负荷剂量缩宫素后,SBP、DBP、MAP下降,而HR、CO、SV升高. Objective To validate whether the application of LiDCOrapid system could provide timely and effective monitoring in oxytocin-induced hemodynamic changes in obstetric patients undergoing caesarean section.Methods Twenty ASA Ⅰ obstetric patients undergoing elective caesarean section were set the continuous noninvasive arterial blood pressure measurement (CNAP) using the LiDCOrapid monitor in operating room.The real-time hemodynamic parameters,including systolic blood pressure (SBP),diastolic blood pressure (DBP),mean arterial pressure (MAP),heart rate (HR),cardiac output (CO) and stroke volume (SV) were recorded by LiDCOrapid-system at the time when parturient entering operating room,baby delivery and every 10 s after the oxytocin administration until 180 s.Oxytocin related side effects were also recorded.Results Following an intravenous bolus of 10 IU oxytocin,the increase of HR,SV,CO and the decrease of SBP,DBP,MAP were observed in all obstetric patients by LiDCOrapid system.These hemodynamic changes recorded by LiDCOrapid system were consistent with LiDCOplus system (an invasive arterial blood pressure measurement) recorded.We used the hemodynamic parameters when the baby delivery as the base value.The largest hemodynamic changes occurred at 40 s-60 s after oxytocin administration,SBP,DBP,MAP,HR,CO,SV changed to (89±12)%,(73±14)%,(81±12)%,(116±12)%,(174±35)%,(150±27)% of the base value respectively at that moment(P〈0.01).Conclusions Compared to LiDCOplus,LiDCOrapid,a reliable non-invasive hemodynamic monitor is useful and sensitive in detecting oxytocin induced hemodynamic changes during caesarean section.Oxytocin induced hemodynamic changes included a rapid increase in HR,CO and SV,and meanwhile a quick decrease in blood pressure.
出处 《国际麻醉学与复苏杂志》 CAS 2015年第4期321-324,329,共5页 International Journal of Anesthesiology and Resuscitation
关键词 LiDCOrapid 剖宫产 缩宫素 血流动力学 无创监测 LiDCOrapid Caesarean section Oxytocin Hemodynamic effects Non-invasive monitor
  • 相关文献

参考文献10

  • 1杨军良,张立生.产科麻醉管理的国际流行趋势——剖宫产术:腰麻、硬膜外还是腰硬联合麻醉.[J].国际麻醉学与复苏杂志,2013,34(4):289-292. 被引量:13
  • 2陈金星,魏青,夏云,赵亚兵,张茂鹏.自控硬膜外分娩镇痛对产程和分娩方式的影响[J].国际麻醉学与复苏杂志,2012,33(12):811-813. 被引量:17
  • 3Gimpl G, Fahrenholz F. The oxytocin receptor system : structure,function, and regulation[j]. Physiol Rev, 2001, 81(2) : 629-683.
  • 4Favaretto AL, Ballejo GO, Albuquerque-Araujo WI, et al. Oxytocinreleases atrial natriuretic peptide from rat atria in vitro that exertsnegative inotropic and chronotropic action [J]. Peptides, 1997, 18(9): 1377-1381.
  • 5Mukaddam-Daher S, Yin YL,Roy J, et al. Negative inotropic andchronotropic effect of oxytocin [j]. Hypertension, 2001, 38(2):292-296.
  • 6Thomas TA,Cooper GM. Maternal deaths from anaesthesia. Anextract from why mothers die 1997 -1999, the confidential enquiriesinto maternal deaths in the United Kingdom [J]. Br J Anaesth,2002,89(3): 499-508.
  • 7Langesaster E,Rosseland LA,Stubhaug A. Hemodynamic effects ofoxytocin in women with severe preclampsia[j]. Int J Obstet Anesth,2011,20(1): 26-29.
  • 8Langesaeter E, Rosseland LA, Stubhaug A. Hemodynamic effects ofoxytocin during cesarean delivery [j]. Int J Gynaecol Obstet, 2006,95(1): 4647.
  • 9Sundar S, Panzica P. LiDCO systems [J]. Int Anesthesiol Clin,2010,48(1): 87-100.
  • 10Rosseland LA, Hauqe TH, Grindheim G, et al. Changes in bloodpressure and cardiac output during cesarean delivery, the effectsof oxytocin and carbetocin compared with placebo [J].Anesthesiology, 2013, 119(3): 541-551.

二级参考文献46

  • 1Brown DL, Gottumukkala V. Spinal, epidural andcaudalanesthesia: anatomy, physiology, and technique. ObstetricAnesthesia: Principles and practice, Third Edition. Philadelphia,Elsevier Mosby, 2004: 172-173.
  • 2Wang FZ, Shen XF, Guo XR. Early labor neuraxial analgesia:effects on the progress and outcome of labor. Anesthesiology,2010,112(4): 1054-1055.
  • 3Wong CA, Scavone BM, Peaceman AM, et al. The risk of cesareandelivery with neuraxial analgesia given early versus late in labor. NEngl J Med, 2005, 352(6): 655-665.
  • 4胡灵群,刘仁玉,杭燕南,等.循证临床麻醉学.2版.北京:人民卫生出版社,2009.
  • 5Sharma SA, Melntire DD, Wiley JR, et al. Labour analgesia andcesarean delivery : an Individual patient meta -analysis ofnulliparous women. Anesthesiology, 2004, 100(8): 142-148.
  • 6Brenda A, David R, David J, et al. A Practical Approach toObstetric Anesthesia.实用产科麻醉学.黄宇光主译.1版.北京,人民卫生出版社,2010: 162-163.
  • 7Kowalski WB, Parsons MT, Pak SC, et al. Morphine inhibitsnocturnal oxytocin secretion and uterine contractions in thepregnant baboon. Biol Reprod, 1998,58(2): 971-976.
  • 8Kuczkowski KM. Implementing safe obstetric anesthesia in Eastern Europe. The Journal of Maternal-Fetal and Neonatal Medicine, 2009, 22(8): 540-645.
  • 9Regan KJ, O'Sullivan G. The extension of epidural blockage for emergency caesarean section: a survey of current UK practice. Anaesthesia, 2008, 63( 1 ) : 136-142.
  • 10Kinsella SM, Walton B, Sashidharan R, et al. Category-1 caesarean section a survey of anaesthetic and peri-operative management in the UK. Anaesthesia, 2010, 65(4): 362-368.

共引文献28

同被引文献26

引证文献6

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部