摘要 为保证核医学成像质量及安全,设备的质量控制必不可少.质量控制为按照特定的标准对设备性能进行专门测试及校正.笔者对国内外核医学成像设备质量控制标准的发展及现状进行调研,并对中国核医学成像设备的质量控制现状进行综述分析,结果显示目前质量控制工作及其标准的可行性有待提高. To assure the quality and safety of nuclear medicine imaging,quality control for the imaging equipment is essential.Quality control consists of a series of special tests for assurance and adjustment of equipment accuracy according to specific standards.The development and status of quality control and the standards for nuclear medicine imaging equipment are investigated and reviewed in this study.The results show that the quality control and feasibility of the standards are both in need of improvement in China.
出处 《中华核医学与分子影像杂志》 北大核心 2015年第1期75-78,共4页 Chinese Journal of Nuclear Medicine and Molecular Imaging
基金 科技部国际科技合作项目(2009DFA32960)
关键词 设备和供应 核医学 质量控制 中国 Equipment and supplies Nuclear medicine Quality control China
  • 相关文献

参考文献27

  • 12012年全国核医学现状普查简报[J].中华核医学与分子影像杂志,2012,32(5):357-357. 被引量:38
  • 2National Electrical Manufacturers Association. NEMA NU 1-1994: Performance measurements of Gamma cameras[S]. Washington DC: NEMA, 1994.
  • 3National Electrical Manufacturers Association. NEMA NU 1-2001: Perfonnance measurements of Gamma cameras[S]. Rosslyn, VA: NEMA,200l.
  • 4National Electrical Manufacturers Association. NEMA NU 1-2007: Performance measurements of Gamma cameras[S]. Rosslyn, VA: NEMA,2007.
  • 5National Electrical Manufacturers Association. NEMA NU 2-1994: Performance measurements of positron emission tomography[S] . Washington DC: NEMA, 1994.
  • 6National Electrical Manufacturers Association. NU 2-2001: Perfonn?ance measurements of positron emission tomography[S]. Rosslyn, VA: NEMA, 200l.
  • 7National Electrical Manufacturers Association. NEMA NU 2-2007: P erfonnance measurements of positron emission tomography[S] . Rosslyn, V A: NEMA, 2007.
  • 8National Electrical Manufacturers Association. NEMA NU 2-2012: Performance measurements of positron emission tomography[S] . Rosslyn, VA: NEMA, 2012.
  • 9National Electrical Manufacturers Association. NEMA NU 4-2008: Performance measurements of small animal positron emission tomo?graphs[S]. Rosslyn , VA: NEMA, 2008.
  • 10International Electrotechnical Commission. IEC 60789 3rd Edition 2OOS: Medical electrical equipment-characteristics and test condi?tions of radionuclide imaging devices-anger type gamma cameras[S]. IEC, 2OOS.

二级参考文献40

  • 1张永学.我国核医学情况调查[J].中华核医学杂志,2003,23(6):383-383. 被引量:9
  • 2张满达,丁虹.我国核医学情况调查报告[J].中华核医学杂志,1993,13(4):246-250. 被引量:3
  • 3高平,秦绍森,蔡晓杰,刘银红,韩丽君,于治国.Alzheimer病与轻度认知功能障碍的脑SPECT显像[J].中华核医学杂志,2006,26(4):213-215. 被引量:9
  • 4张春银,李作孝,陈跃,谭华,李晓红.脑出血患者缺血性脑损害局部脑血流灌注的SPECT显像[J].中华核医学杂志,2006,26(5):290-292. 被引量:3
  • 5Lass P. The situation of nuclear medicine in Central and Eastern Europe [J]. Eur J Nucl Med Mol Imaging, 2005, 32(12): BP11- BP14.
  • 6Hart D, Wall BF. UK nuclear medicine survey 2003-2004 [J]. Nucl Med Commun, 2005, 26(11): 937-946.
  • 7Lio M. Nuclear medicine in the People's Republic of China [ J ]. J Nucl Med, 1979, 20(5): 453-455.
  • 8Wang SC, Chou C. Current status of nuclear medicine in China[J ]. Chin Med J(Engl), 2000, 113(5): 387-391.
  • 9Zhou QA. Advances in nuclear medicine in China[J ]. Chin Med J (Engl), 1990, 103(1): 80-83.
  • 10Norberg P,Bake B,Jacobsson L,et al.Evaluation of reconstruction techniques for lung single photon emission tomography:a Monte Carlo study.Nucl Med Commun,2007,28:929-936.

共引文献105

同被引文献178

引证文献28

二级引证文献115

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部