摘要
目的:探讨采用自制简易单孔器行单孔腹腔镜全腹膜外腹股沟疝修补术( SILS-TEP术)的安全性和可行性。方法:病例来自2013年2~4月浙江大学医学院附属邵逸夫医院普外科。采用一次性切口牵开固定器、无菌手套和普通腹腔镜套管制成简易单孔器,使用常规腹腔镜器械对7例腹股沟疝患者行SILS-TEP术,总结患者的临床资料和随访结果。结果:全部7例(9侧)腹股沟疝患者均行SILS-TEP术成功,中位手术时间90.0(70~125) min,中位出血量10.0(5.0~20.0) mL,中位住院天数2.0(2.0~4.0) d,术后患者疼痛轻微,无围手术期并发症。随访3个月切口愈合佳,均无复发及其他并发症发生。结论:采用自制简易单孔器行SILS-TEP术初步经验显示安全可行,该方法能简化单孔手术器械,减轻患者经济负担,易于基层医院推广应用。
Objective: To explore the feasibility of single-incision laparoscopic totally extraperitoneal hernioplasty ( SILS-TEP ) with self-made port for repairing of inguinal hernia .Methods: SILS-TEP was performed in 7 inguinal hernia patients ( 9 sides) with conventional laparoscopic instruments and self-made port, which composed of a wound retractor , surgical gloves and 3 ordinary trocars .The clinical data and fellow-up results of 7 cases were retrospectively collected and analyzed .Results: The self-made port was applied for SILS-TEP uneventfully without the need of additional ports in all 7 patients (9 inguinal hernias).The median operating time was 90.0 (70-125) min, intraoperative blood loss was 10.0 ( 5.0 -20.0 ) mL and postoperative hospital stay was 2.0 ( 2.0 -4.0 ) d.The median pain scores of visual analog scale (VAS) at 6 h,12 h, 24 h and 14 d were 3(2~4), 2(1~2), 1(0~2) and 0(0~1 ) , respectively .There were no intraoperative complications reported , and all patients were satisfied with wound healing . No hernia recurrence was observed during the 3-months of follow-up.Conclusion: Our initial experiences show that SILS-TEP with self-made port is s safe and feasible surgery , which can simplify the procedure with available equipments and reduce the cost , therefore can be applied in grass-root hospitals .
出处
《浙江大学学报(医学版)》
CAS
CSCD
北大核心
2015年第1期79-84,共6页
Journal of Zhejiang University(Medical Sciences)
基金
浙江省教育厅基金资助项目(Y201326835)