摘要 MRI技术的发展突飞猛进,在医学影像诊断及科研领域发挥着越来越重要的作用。纵观MRI技术的发展历程,技术引领设备的进步,设备促进技术的进展,二者相辅相成。笔者从设备硬件及技术发展两方面探讨MRI技术的新进展。
出处 《中华放射学杂志》 CAS CSCD 北大核心 2015年第4期251-253,共3页 Chinese Journal of Radiology
  • 相关文献

参考文献20

  • 1Katscher U, Bomert P. Parallel RF transmission in MRI[J].NMR Biomed, 2006,19(3):393-400.
  • 2Berker Y,Franke J, Salomon A, et al. MRI-based attenuationcorrection for hybrid PET/M RI systems: a 4-class tissuesegmentation technique using a combinedultrashort-echo-time/Dixon MRI sequence[J]J Nucl Med,2012, 53(5):796-804.
  • 3Schwenzer NF, Schmidt H, Claussen CD. Whole-body MR/PET: applications in abdominal imaging[J].Abdom Imaging,2012,37(1):20-28.
  • 4常飞燕,谢晟,李中实,刘卉,王武.利用三维伪连续脉冲动脉自旋标记测量颈性眩晕相关的脑血流量改变的初步研究[J].中华放射学杂志,2014,48(1):25-28. 被引量:18
  • 5Vidorreta M,Wang Z, Rodriguez I, et al. Comparison of 2Dand 3D single-shot ASL perfusion fMRI sequences[J].Neuroimage, 2013, 66:662-671.
  • 6娄昕,吴冰,黄点点,吴新淮,吴南洲,马林.正常成人后循环脑区动脉自旋标记灌注成像的可重复性研究[J].中华放射学杂志,2014,48(2):151-154. 被引量:62
  • 7Dixon WT. Simple proton spectroscopic imaging[J].Radiology, 1984, 153(1):189-194.
  • 8Clendenen TV, Zeleniuch-Jacquotte A, Moy L, et al.Comparison of 3-point Dixon imaging and fuzzy C-meansclustering methods for breast density measurement[J].J MagnReson Imaging, 2013,38(2):474-481.
  • 9He Q, Weng D, Zhou X, et al. Regularized iterativereconstruction for undersampled BLADE and its applicationsin three-point Dixon water-fat separation[J].Magn ResonMed, 2011,65(5):1314-1325.
  • 10刘伟,邸强,赖云耀,洪楠,郝传玺.采用3.0T MR不同分析方法进行体外模型脂肪定量分析的价值[J].中华放射学杂志,2014,48(12):1033-1037. 被引量:30

二级参考文献76

共引文献172

同被引文献32

  • 1周建威,杨保联,李丽云,胡红兵,裘鉴卿,叶朝辉.动态核极化核磁共振波谱学[J].物理,1996,25(3):160-166. 被引量:3
  • 2梁明理,周建平,刘军,梁裕蓉,胡家元,郭煜,万纯祥.测试生物样品的ESR成像系统[J].波谱学杂志,1990,7(3):351-357. 被引量:5
  • 3Liu F,Coursey CA,Grahame-Clarke C,et al.Aortic valve calcification as an incidental finding at CT of the elderly.severity and location as predictors of aortic stenosis[J].Am J Roentgenol,2006, 186(2):342-349.
  • 4Kon MW,Myerson SG,Moot NE,et al.Quantification of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance:comparison of technique[J]J Heart Value Dis, 2004,13(4):600-607.
  • 5Sondergaard L,Lindvig K,Hildebrande P,et al.Quantification of aortic regurgitation by magnetic resonance velocity mapping[J]. Am Heart J,1993,125(4):1081-1090.
  • 6Martin G.St John Sutton,Alan R.Maniet.Mitral valve transesophageal echocardiography[M].Oxon:Taylor & Francies, 2006:18-30.
  • 7Lawrence MB.CT ofvalvuar heart disease[J].Int J Cardiovascular Imaging,2005,21(1):105-113.
  • 8Willmann JK,Weishaupt D,Kobza R,el al.Electrocardiographically gated muti-detector row CT for assessment of valvular morphology and calcification in aorticstenosis[J].Radiology,2002, 225(2):120-128.
  • 9Lamas GA,Mitchell GF,Flaker GC,el al.Clinical significance of mitral regurgitation after acute mayocardial infarction .Survival and Ventricular Enlargment Investigators[J].Circulation, 1997,96(3):827-833.
  • 10Konstantinou DM,Papadopoulou K,Giannakoulas G,et al. Determinants of functional mitral regurgitation severity in patienrs with ischemic cardiomyopathy versus nonischemic dilated cardiomypathy[J].Echocardiography,2014,31 (1):21-28.

引证文献6

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部