期刊文献+

地板辐射供暖地基由热桥引起的热损失

The Heating Loss Led By Thermal Bridge Of The Radiant Heating Of Floor
下载PDF
导出
摘要 本文对通过墙和厚板交界处热桥的热损失进行了简述。首先,讨论了通过热桥的热损失。特别是由于地板辐射而引起的通过热桥的附加热损失。此外,提供了通过墙和厚板交界处的热桥总的热损失的详尽描述。其结果可用于计算通过一座建筑物围护结构的热损失。 The particle gives detailed summary for the heating loss led by the junction of wall and thick plate. At the beginning,the heating loss led by thermal bridge is discussed,especially for the heating loss led by thermal bridge of the radiant heating of floor. In addition,it also provides the detailed information for the total heating loss led by the junction of wall and thick plate. The results can be used to calculate the heating loss from building envelope of one building.
出处 《林业科技情报》 2015年第1期66-67,共2页 Forestry Science and Technology Information
关键词 热桥 热损失 地板辐射供暖 thermal bridge heating loss floor radiant heating