摘要 胎儿监护仪是一种已经广泛应用于临床的医疗器械,超声波对胎儿的损伤虽然尚未有医疗界定,但临床上仍需通过提高胎儿监护仪超声波信号的发射效率以及回波信号的接收灵敏度来降低超声波信号强度,以避免未知损伤的发生。本文基于分立元件设计了可用于胎儿监护仪的超声发射、接收和解调电路,能够降低集成电路形式的电源损耗,可通过阻抗匹配和多级谐振放大提高回波信号的接收灵敏度,且电路结构简单,解调效率高。测试验证结果表明整体电路的性能较好。 The ultrasound fetal monitor has been a kind of clinically widely-used medical devices. Although ultrasound’s damage to fetuses is still ill-deifned, the transmitting efifciency of the fetal monitor’s ultrasound signals and the receiving sensitivity of echo signals need to be increased to reduce the signal intensity of ultrasound and avoid the occurrence of un-known damages in its clinical application. In this paper, the simply-structured transmitter, receiver demodulation circuits are constructed based on the separate components to reduce the power loss and consumption of integrated circuits. With the characteristics of high efifciency of demodulation, the circuits can increase the receiving sensitivity of echo signals through impedance matching and multi-stage resonance ampliifcation. The whole circuit has demonstrated its outstanding performance in the veriifcation test.
出处 《中国医疗设备》 2015年第4期22-24,27,共4页 China Medical Devices
关键词 胎儿监护仪 超声换能器 发射电路 接收电路 解调电路 fetal monitor ultrasound transducers transmitter circuit receiver circuit demodulation circuit
  • 相关文献

参考文献8

二级参考文献54

  • 1袁建人.国外医疗超声换能器的应用、研究和发展[J].中国医疗器械信息,2004(5):48-52. 被引量:4
  • 2郭建中,林书玉,郭勇亮.压电换能器电端匹配电路的优化[J].测控技术,2004,23(8):73-75. 被引量:12
  • 3林书玉.匹配电路对压电陶瓷超声换能器振动性能的影响[J].压电与声光,1995,17(3):27-30. 被引量:14
  • 4S A Shakespeare, J A Crowe, B R Hayes-Gill, K Bhogal, D K James. The information content of Doppler ultrasound signals from the fetal heart [J]. Medical & Biological Engineering & Computing, 2001, 39.
  • 5B Karlsson, K Foulquiere, K Kaluzynski, et al. THE DopFet SYSTEM: A New Ultrasonic Doppler System for Monitoring and Characterization of Fetal Movement [J]. Ultrasound in Med. &Biology, 2000, 26(7): 1117-1124.
  • 6Yasuaki Noguchi, Suguru Sugimoto, Atsushi Yoshida, Hisaaki Kobayashi, Mitsanao Koayshi. Measurement Accuracy of Ultrasound Heart Rate Monitor [A]. IEEE-EMBC and CMBEC [C]. 1995.
  • 7Hans W Persson, Stephan O Dymling, Nils-Gunnar Holmer. A Measurement System for Continuous Wave Ultrasound Field [J]. Ultrasound In Medical & Biology, 1991, 17: 501-504.
  • 8RobeH.Bishop.LabVIEW7使用教程[M].乔瑞萍,林欣,译.北京:电子工业出版社,2005:28-40.
  • 9方由艳,高炳山.匹配网络对换能器谐振频率影响的研究[J].声学技术,2009,28(2):51-52.
  • 10Garcia-Rodriguez M,Garica-Alvarez J, Yafiez Y,et al. Low cost matching network for ultrasonic transducer[J]. Physics Procedia ,2010,3( 1 ) : 1025-1031.

共引文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部