摘要
文章在现有安全阀设计标准和规范基础上,分析了火灾工况、回流中断、冷凝器故障等几种常见的精馏塔安全阀超压工况,总结出不同工况下泄放量计算方法,对安全阀泄放量计算取值基准问题进行研究和讨论,可为工程设计人员提供参考。
The article in the existing standards and norms of safety valve design, analyzed several common condition of distillation tower ,such as fire, reflux interrupt and condenser fault, summarized the calculating methods of relieving capacity under different conditions, value benchmark problems on the calculation of relieving capacity is studied and discussed, which can provide reference for engineering design personnel.
出处
《广东化工》
CAS
2015年第7期145-146,共2页
Guangdong Chemical Industry
关键词
安全阀
泄放量
火灾工况
回流中断
冷凝器故障
safety valve: relieving capacity fire conditions: reflux interrupt
condenser fault