空中爆炸冲击作用下不同接头形式埋地管线动力响应的对比试验研究 被引量:2

Comparative Experimental Study of Dynamic Response of Buried Pipeline with Different Joints Subjected to Blast Shock Loading in Air Explosion
原文传递
导出
摘要 为探明爆炸冲击条件下管线接头部位受力变形的特点和规律,在室内爆炸试验碉堡测试系统内分别对直管线、带直接头和弯头管线动力响应情况进行对比试验研究,测试了接头连接处迎爆面及其背面的轴向应变,并对测试结果进行了对比分析。结果表明,管径突变会产生应力集中,接头部位是管线系统的薄弱环节;接头的厚径比是影响接头部位防爆抗震性能的重要参数;接头的类型是影响管线系统防爆抗震性能的重要因素,在管线设计中要尽量减少弯头数量,设置橡胶软接头可增强管线系统防爆抗震性能。 In order to ascertain the deformation feature of buried pipeline joints subjected to blast shock loading in air explosion,a comparative experimental study of dynamic response for straight pipeline and pipeline with straight joint and elbow was carried out separately by using an indoor bunker measurement system.Axial strain on the surface facing blast and on the back surface of pipeline joint was measured separately and comparatively analyzed.Results show that pipe diameter abrupt change may cause stress concentration,so joint region is the weaknesses of pipeline.The thickness-diameter ratio of joint is an important parameter affecting its seismic performance of explosion-proof.The form of joint is another important factor affecting its seismic performance of explosion-proof.So,in pipeline design,the number of elbow should to be minimized as possible and the application of soft rubber joint can enhance pipeline's seismic performance of explosion-proof.
出处 《实验力学》 CSCD 北大核心 2015年第2期192-198,共7页 Journal of Experimental Mechanics
基金 国家自然科学基金项目(11102233):爆炸地冲击荷载下土中冲液压力圆柱壳动力屈曲研究 总后营房部项目:军事工程管线系统综合防护方案研究(CY211J038)
关键词 空爆 埋地管线 对比试验 接头 应变 air blast buried pipeline comparative experiment joint strain
  • 相关文献

参考文献9

二级参考文献33

共引文献116

同被引文献23

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部