摘要
结合某玻璃厂油罐区的工程设计实例,详细介绍了油罐区的消防系统设计,包括泡沫灭火系统、消防冷却水系统及泡沫消防泵房的设计。
Based on the design practice of tank farm in a glass factory, the design of fire control system for oilcan zone, design of foam extinguishing system, design of cooling water system and design of foam system pump station were introduced in details.
出处
《玻璃》
2015年第4期33-36,共4页
Glass
关键词
固定顶油罐
低倍数泡沫灭火系统
消防冷却水系统
玻璃厂
fixed-roof oil tank, low-expansion foam extinguishing system, fire cooling water system, glass factory