摘要
以福建鼎信1 550 mm连续退火酸洗线卷取机为研究对象,找出了其钳口处的漏油问题,从液压系统设计与机械结构设计两方面做了相应改进,从而使漏油问题得到解决,保证了带钢产品的表面质量。
It is researched the oil leakage of the bite of coiler of 1 550 mm continuous annealing pickling line of Dingxin in Fujian, the corresponding improvement in hydraulic system design and machinery structure design made, and then the oil leakage is solved, the surface quality of strip steel guaranteed.