期刊文献+

预注小剂量间羟胺对缩宫素所致剖宫产产妇血流动力学变化的影响 被引量:12

Effects of small dose of aramine pre-injection on hemodynamic fluctuations caused by administration of oxytocin during cesarean section
下载PDF
导出
摘要 目的 探讨腰麻下剖宫产术中预注小剂量间羟胺对缩宫素所致血流动力学变化的影响.方法 腰麻下行剖宫产术且同意术中连续心排血量(CO)监测产妇40例,随机分为O组和A组,每组20例.结扎脐带前O组和A组分别静注生理盐水1 ml和间羟胺0.25 mg(1 ml).结扎脐带后两组均注射缩宫素10U(1ml).记录注射缩宫素后300 s内产妇的HR、MAP、CO和体循环阻力(SVR)的变化.结果 与注射缩宫素前即刻(0 s)比较,注射缩宫素后40~120 s时O组MAP明显降低(P<0.01),而A组各时点均无明显变化;20~90 s时O组HR逐渐增快(P<0.01),而A组HR变化比较平缓,且明显慢于O组(P<0.01);20~90 s时产妇CO均明显增加(P<0.01),但A组明显低于O组(P<0.01);20~240 s时O组SVR明显降低(P<0.01),而A组SVR明显高于O组(P<0.01).结论 腰麻下行剖宫产术中预注小剂量间羟胺可抵消缩宫素对心血管的不良反应,平稳血流动力学的波动. Objective To observe the effects of small dose of aramine pre-injection on hemody- namic fluctuations caused by administration of oxytocin during cesarean section under spinal anesthe sia. Methods Forty patients undergoing selective cesarean section under spinal anesthesia were as signed randomly to one of the two groups: group O received 0. 9% normal saline 1 ml before umbilical occlusion, and group A received aramine 0.25 mg (1 ml) before umbilical occlusion. Both group O and group A received oxytocin 10 U (1 ml) after umbilical occlusion. Hemodynamic parameters were con tinuously obtained at 9 main time-points. Results After oxytocin injection, MAP of group O dramat- ically declined at 40-120 s (P〈0.01), while MAP were stable at every time-point compared with 0 s in group A. Compared to 0 s, HR was significantly increased at 20-90 s in group O (P〈0. 01), while HR at the other time-points were no significantly difference in group A compared with 0 s. CO was dramatically increased at 20-90 s compared with 0 s in both groups (P〈0.01), but the increase of the former was significantly increase compared with group A (P〈0.01). In group O , SVR significantly decreased at 20-240 s compared with 0 s, while SVR was no significantly difference at 20-90 s in group A. Conclusion Intravenous pre-injection of small dose of aramine can ameliorate hemodynamic fluctuations during cesarean section under spinal anesthesia
出处 《临床麻醉学杂志》 CAS CSCD 北大核心 2015年第4期326-328,共3页 Journal of Clinical Anesthesiology
关键词 间羟胺 缩宫素 剖宫产 血流动力学 Aramine Oxytocin Cesarean section Hemodynamics
  • 相关文献

参考文献6

  • 1Edhi MM, Aslam HM, Naqvi Z, et al. Post partum hemor- rhage: causes and management. BMC Res Notes, 2013, 6 (1),236.
  • 2Langes eter E, Rosseland LA, Stubhaug A. Haemodynamic effects of oxytocin in women with severe preeclampsia. Int J Obstet Anesth, 2011, 20(1) :26-29.
  • 3Arag o FF, Arag o PW, Martins CA, et al. Comparison of metaraminol, phenylephrine and ephedrine in prophylaxis and treatment of hypotension in cesarean section under spinal anes- thesia. Braz ] Anesthesiol, 2014, 64(5) :299-306.
  • 4李仁奇,曾秋婷,田蜜,纪木火,李伟彦.缩宫素对剖宫产产妇术中血流动力学的影响[J].临床麻醉学杂志,2013,29(4):362-364. 被引量:29
  • 5Rosseland LA, Hauge TH, Grindheim G, et al. Changes in blood pressure and cardiac output during cesarean delivery the effects of oxytocin and carbetocin compared with placebo. An- esthesiology, 2013, 119(3):541-551.
  • 6Dyer RA, Pierey JL, Reed AR, et aL Hemodyr amic changes associated with spinal anesthesia for cesarean delivery in severe preeclampsia. Anesthesiology, 2008, 108(5):802-811.

二级参考文献9

  • 1Lalonde A, Daviss BA, Acosta A, et al. Postpartum hemorrhage today: ICM/FIGO initiative 2004-2006. Int J Gynaecol Obstet, 2006, 94(3): 243-253.
  • 2Dyer RA, Piercy JL, Reed AR, et al. Hemodynamic changes associated with spinal anesthesia for cesarean delivery in severe preeclampsia. Anesthesiology, 2008, 108(5): 802-811.
  • 3Zingg HH, Laporte SA. The oxytocin receptor. Trends Endocrinol Metab, 2003, 14(5): 222-227.
  • 4Barin E, Haryadi DG, Schookin SI, et al. Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac cathe-terization. Crit Care Med, 2000, 28(3): 698-702.
  • 5Seitchik J, Amico J, Robinson AG, et at. Oxytocin augmentation of dysfunctional labor. IV. Oxytocin pharmacokinetics. Am J Obstet Gynecol, 1984, 150(3): 225-228.
  • 6Woo C, McGlennan A. Minimum effective bolus dose of oxytocin during elective Caesarean delivery. Br J Anaesth, 2010,105(1): 91-92.
  • 7Sartain JB, Barry JJ, Howat PW, et al. Intravenous oxytocin bolus of 2 units is superior to 5 units during elective Caesarean section. Br J Anaesth, 2008, 101(6): 822-826.
  • 8King KJ, Douglas MJ, Unger W, et al. Five unit bolus oxytocin at cesarean delivery in women at risk of atony: a randomized, double-blind, controlled trial. Anesth Analg, 2010, 111 (6):1460-1466.
  • 9殷静瑜,王志群,胡娅莉,李洁,戴毅敏,顾宁,张书敏.江苏基层医院产后出血防治现状调查[J].江苏医药,2010,36(7):750-753. 被引量:2

共引文献28

同被引文献99

引证文献12

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部