摘要
利用比值法原理,选取不同环境,在80 k Hz^500 k Hz频段内,对低压电力线的阻抗和信道噪声进行了测量,并对所测数据进行处理计算。分析电力线网络中不同时间段通信频点的阻抗变化范围与信道中脉冲噪声特性的关系。分析结果表明:在80~500 k Hz频段内,输入阻抗变化范围与信道脉冲噪声数量和功率有同增同减的关系;阻抗具有很强的时变性;电网结构及负载类型、数量对阻抗变化范围影响较大。
Choosing different environments on campus,the impedance of the low-voltage power line and channel noise in the range of 80 ~ 500 k Hz was measured by ratio method principle. Process and calculate the data obtained by collection,and then analyze the relationship between impulse noise characteristics and communication frequency impedance variation on low-voltage power line in different times. The analysis of results show that: in the range of 80 ~ 500 k Hz,the input- impedance variation and the number and power of impulse noise has the relationship of increasing or decreasing synchronously; Impedance has a strong time- varying;The impedance variation can be seriously influenced by the structure of the power grid,load type and quantity.
出处
《云南电力技术》
2015年第1期47-50,共4页
Yunnan Electric Power
基金
云南省重点科技项目"电力载波设备通信性能测试方法
测试规范及设备验收规范的研究"
国家自然科学基金(KKGD201203004)
关键词
低压电力线
通信频点
阻抗变化范围
脉冲噪声
阻抗与噪声关系
low-voltage power line
communication frequency
impedance variation range
impulse noise
relationship of impedance and noise