期刊文献+

测偏仪运行中常见故障分析及解决方法 被引量:1

Analysis and Resolution of XRAY 8000 NXT Problems during Operation
下载PDF
导出
摘要 简叙了中高压电缆交联生产线中测偏仪在运行中出现的几种常见故障,如无法实现自动控制功能、高压曲线出现凹陷、冷却水流量不足或水温过高、扫描头漏油等,分析了产生原因并提出了相应的解决办法。 This article introduces some problems and the reasons analysis of XRAY NXT 8000 during its operation in medium and high voltage CCV cable lines, such as auto control function failure, high voltage video fault, cooling water flow insufficient or high temperature, scanner leaking oil, some concrete measures are proposed to resolve these problems.
作者 唐朝霞
机构地区 烟台市电缆厂
出处 《电线电缆》 2015年第2期41-43,46,共4页 Wire & Cable
关键词 测偏仪 自动控制 原始图像 冷却水 漏油 高压 测量数据 XRAY 8000 autocontrol original video cooling water leaking oil high voltage scan dates
  • 相关文献

参考文献2

  • 1《电线电缆手册》编委会.电线电缆手册(第2册)[M].北京:机械工业出版社,2009.
  • 2Li W M, Li S H, Zhang Q Y, et al. Synthesis of bis(amine anhydride)s for novel high Tgs and organosoluble poly(amine imide) s by palladium-catalyzed amination of 4-chlorophthalide anhydride [ J ]. Macromolecules, 2007,40: 8205-8211.