期刊文献+

Q值引导与标准化准分子激光原位角膜磨镶术术后角膜非球面系数Q值变化的远期观察 被引量:1

Long-Term Observation on Changes of Q Values after Q-Guided Aspheric Ablation and Standard Ablation in LASIK
原文传递
导出
摘要 目的观察Q值引导和标准准分子激光原位角膜磨镶术(laser in situ keratomilieusis,LASIK)术后角膜Q值的远期变化趋势,探讨Q值引导LASIK术对维持角膜非球面状态的有效性。方法回顾分析2008年12月至2013年12月,低中度近视患者80例80只眼,分为Q值引导准分子激光手术(Q-value-guided excimer laser surgery,Q-LASIK)组和标准准分子激光手术(Standard excimer laser surgery,S-LASIK)组,每组患者40例40只眼。所有病例跟踪随访3年和3年以上,观察术后角膜Q值的变化趋势。结果术后1、3、6、12、24和36个月,两组患者术后角膜Q值比较,差异有显著意义(P<0.05)。两组患者术后6个月内的Q值变化明显,两组患者术后的Q值均向负值方向变化;术后6个月,两组患者的角膜Q值均基本稳定。结论 Q-LASIK组与S-LASIK组比较,能更好地维持角膜的非球面特性,疗效稳定。 Objective To observe the long-term developing trend of the corneal Q value after Q-value-guided aspheric ablation and standard LASIK and explore the effectiveness of Q-value-guided LASIK surgery in maintaining the corneal aspherieal state. Methods From December 2008 to December 2013, Altogether 80 cases (80 eyes) of patients with low to moderate myopia that had received Q-value-guided excimer laser surgery (Q-LASIK) and standard excimer laser surgery (S-LASIK) were selected and followed up for three or more years, and the development trend of the corneal Q value was analyzed. Results At Month 1, 3, 6, 12, 24 and 36 after the operation, the two sets of results for repetitive measure analysis of variance were significantly different (P 〈 0.05 ). Within the 6 months after the operation, the Q values of both groups changed dramatically, the difference between the two groups was significant and the Q values of both groups changed toward the negative end. After Month 6, the Q values of both groups were basically stable. Conclusions Q-LASIK maintains corneal aspherical properties better than S-LASIK and the effect was stable.
机构地区 解放军第
出处 《中国激光医学杂志》 CAS CSCD 2014年第6期341-344,共4页 Chinese Journal of Laser Medicine & Surgery
关键词 非球面切削 Q值 准分子激光原位角膜磨镶术 Aspherical ablation Q-value Excimer laser in situ keratomilieusis
  • 相关文献

参考文献6

  • 1Packer M, FineI H, Hoffnmn RS. Functional vision, wavefront sensing, and cataract surgery[J]. Int Opht hal- tool Clin, 2003, 43:79-91.
  • 2Carney LG, M ainstone JC, Henderson BA. Corneal to- pography and myopia. Across sectional study [ J ]. Invest Ophthalmol Vis Sci, 1997, 38:311-320.
  • 3Hersh PS , Fry K, Blaker JW. Spherical aberration after laser in situ keratomil eusis and photorefractive keratecto- my. Clinical results and theoreticalm odels of etiology [J]. J Cataract Surg , 2003, 29:2096-2104.
  • 4Holladay JT, Dudeja DR, Chang J. Functionalvision andcorn ealchanges after laser in situ kerato mileusis deter mined by contrast sensitivity, glaretesting, and corneal to- pography[J]. JC ataract Refract Surg, 1999, 25: 663- 669.
  • 5Catine 1D, Malet J, Hoang Xuan T, et al. Analysis of cus- tomiz edcorneal ablations: theoretical limitations of in- creasing negative as phericity[J]. In vest Opht halmo 1V is Sci, 2002,43: 941-948.
  • 6Manns F, Ho A, Parel JM, et al. Ablation profiles for wavefront guided correction of myopia and primary spheri- cal aberration [ J ]. JC ataract Refract Surg, 2002, 28 : 766-774.

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部