期刊文献+

心脏移植患者术后心电图特征70例分析 被引量:1

Analysis of Electrocardiogram Characteristics by Postoperative Follow-Up in 70 Patients with Heart Transplantation
下载PDF
导出
摘要 目的:探讨采用双腔静脉吻合术行原位心脏移植的患者术后心电图的特征和临床意义。方法:回顾分析2009—2012年在复旦大学附属中山医院采用双腔静脉吻合术行原位心脏移植的70例患者的术后随访心电图检查结果。结果:患者术后的平均心室率较快,心电图表现多见非缺血性ST-T改变、V1导联P波终末电势(P terminal force in lead V1,Ptfv1)增大和不完全性右束支阻滞。偶见的心室率缓慢、缺血性ST-T改变及心律失常等现象则提示预后不良。结论:对于采用双腔静脉吻合术行原位心脏移植的患者,术后心电图的特征性表现有助于判断患者的预后。 Objective:To explore the postoperative electrocardiogram characteristics and its clinical significance in patients who had undergone orthotopic heart transplantation with double vena cava anastomosis.Methods:The electrocardiogram results of70 patients during postoperative follow-up,who underwent orthotopic heart transplantation with double vena cava anastomosis in Zhongshan Hospital,Fudan University from2009 to 2012,were retrospectively analyzed.Results:The patients' average ventricular rate was a bit faster than normal after operation,and the common phenomena of electrocardiogram were nonischemic ST-T changes,increasing P terminal force in lead V1(Ptfv1)and incomplete right bundle branch block(IRBBB).The rare phenomena such as slow ventricular rate,ischemic ST-T changes and arrhythmia,however,indicated poor prognosis.Conclusions: The postoperative electrocardiogram characteristics in patients who have undergone orthotopic heart transplantation with double vena cava anastomosis are conducive to predicting the patients' prognosis.
出处 《中国临床医学》 2015年第1期89-92,共4页 Chinese Journal of Clinical Medicine
关键词 心脏移植 双腔静脉吻合术 心电图 Heart transplantation Double vena cava anastomosis Electrocardiogram
  • 相关文献

参考文献5

二级参考文献18

  • 1程沛,张英川,林训生.心脏移植术后窦房结功能异常(附1例报道)[J].心肺血管病杂志,1994,13(4):207-209. 被引量:1
  • 2张楠,郭继鸿.抗心律失常药物对心脏起搏阈值的影响[J].中华心律失常学杂志,2006,10(5):389-391. 被引量:9
  • 3周勇,李莉.疑为非甾体类抗炎药引起的起搏器置入后阈值升高一例[J].中国心脏起搏与心电生理杂志,2007,21(3):195-195. 被引量:2
  • 4Zieroth S, Ross H, Rao V, et al.Permanent pacing after cardiac transplantation in the era of extended donors[J]. J Heart Lung Transplant, 2006,25(9):1 142.
  • 5Tsai VW, Cooper J, Garan H, et al. The efficacy of implantable cardioverter-defibrillators in heart transplant recipients: results from a multicenter registry[J]. Circ Heart Fail, 2009,2(3):197.
  • 6Apor A, Kutyifa V, Merkely B, et al.Successful cardiac resynchronization therapy after heart transplantation[J]. Europace, 2008,10(8):1 024.
  • 7Luebbert JJ, Lee FA, Rosenfeld LE. Pacemaker therapy for early and late sinus node dysfunction in orthotopic heart transplant recipients: a single-center experience[J].PACE, 2008,31(9):1 108.
  • 8Cantillon DJ, Gorodeski EZ, Caccamo M, et al. Long-term outcomes and clinical predictors for pacing after cardiac transplantation[J].J Heart Lung Transplant, 2009,28(8):791.
  • 9Woo GW, Schofield RS, Pauly DF, et al. Incidence, predictors, and outcomes of cardiac pacing after cardiac transplantation: an 11-year retrospective analysis[J].Transplantation, 2008,85(8):1216.
  • 10Tay AE, Faddy S, LimS,et al. Permanent pacing for late-onset at-rioventricular block in patients with heart transplantation : a singlecenter experience. Pacing Clin Electrophysiol,2011,34:72-75.

共引文献10

同被引文献12

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部