摘要 选取了8种典型含二甲胺结构化合物,研究这些物质在氯胺、自由氯和二氧化氯消毒条件下的二甲胺(DMA)释放特性和二甲基亚硝胺(NDMA)生成特性,并重点关注氯胺消毒条件下消毒剂剂量、pH和反应时间对NDMA生成的影响。在氯胺消毒条件下,这些化合物可以显著生成NDMA,但不同化合物具有不同的生成特性。研究显示,中间产物DMA的不同释放特性是造成不同物质NDMA生成量存在差异的主要原因。消毒剂剂量和pH均会影响NDMA的生成,其中消毒剂剂量越大,NDMA生成量越大;中性偏碱性条件有利于NDMA生成。
出处 《给水排水》 CSCD 北大核心 2015年第5期118-122,共5页 Water & Wastewater Engineering
基金 国家自然科学基金重大项目(51290284) 清华大学自主科研计划项目(20131089247)
  • 相关文献

参考文献20

  • 1Mitch W A, Sharp J O, Trussell R R, et al. N nitrosodimethy- la mine (NDMA) as a drinking water contaminant: a review. Environ Eng Sci, 2003, 20(5): 389-404.
  • 2Taguchi V Y, Jenkins S W D. Determination of N-nitrosodime- thyla mine by isotope dilution, high-resolution mass spectrome try. Can J Appl Spectrosc, 1994, 39(3): 87-93.
  • 3Charrois J W A, Boyd J M, Froese K L, et al. Occurrence of N nitrosa mines in Alberta public drinking distribution systems. Environ. Eng Sci, 2007, 6(1): 103-114.
  • 4Park S H. Effect of a mine-based water treatment polymers on the formation of N-nitrosodimethyla mine (NDMA) disinfection by-prod- uct. Dissertation, Georgia Institute of Technology, 2008.
  • 5US EPA. http.-//water, epa. gov/lawsregs/rulesregs/sdwa/uc- mr/data, cfm:- ucmr2010.
  • 6王成坤.饮用水中亚硝胺消毒副产物的分布、生成与控制技术研究:[学位论文].北京:清华大学,2012.
  • 7梁闯,徐斌,夏圣骥,高乃云,李大鹏,田富箱.SPE/LC/MS/MS检测水中痕量二甲基亚硝胺[J].中国给水排水,2009,25(14):82-85. 被引量:34
  • 8US EPA. Intergrated Risk Information Service (IRIS) Sub-stance File, 1997.
  • 9US EPA. Unregulated Contaminant Monitoring Rule 2. Wash- ington DC, USA, 2006.
  • 10US EPA. http: // water, epa. gov/scitech/drinkingwater/ dws/cel.

二级参考文献9

  • 1Choi J,Valentine R L.Formation of N-nitrosodimethylamine (NDMA) from reaction of monochloramine:a new disinfection by-product[J].Water Res,2002,36 (4):817 -824.
  • 2USEPA.Integrated Risk Information Service[R].USA:United States Environmental Protection Agency,Office of Research and Development,National Center for Environmental Assessment,1991.
  • 3Charrois J W A,Arend M W.Detecting N-nitrosamines in drinking water at nanogram per liter levels using ammonia positive chemical ionization[J].Environ Sei Technol,2004,38 (18):4835-4841.
  • 4EPA/600/R-05/054,Determination of Nitrosamines in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography with Large Volume Injection and Chemical Ionization Tandem Mass Spectrometry (MS/MS)[S].
  • 5OME.The Determination of N-nitrosodimethylamine (NDMA) in Water by Gas Chromatography-high Resolution Mass Spectrometry (GC-HRMS)[R].Canada:Ontario Ministry of Environment,2004.
  • 6Cheng R C.Alternative Methods for the Analysis of NDMA and Other Nitrosamines in Water and Wastewater,Report WRF-O1-001[R].Long Beach,California:Water Reuse Foundation,2006.
  • 7Yuan Yuan Zhao,Jessica Boyd Characterization of new nitrosamines in drinking water using liquid chromatography tandem mass spectrometry[J].Environ Sei Technol,2007,40(24):7636 -7641.
  • 8Megan H Plumlee.N-nitrosedimethylamine (NDMA) removal by reverse osmosis and UV treatment and analysis via LC-MS/MS[J].Water Res,2007,36(4):817 -824.
  • 9Drinking water surveillance program summary report for 2000,2001 and 2002[DB/OL].http://www,ene.gov.ca/envision/water/dwsp/0002/index,htm,2004-05 -28.