期刊文献+

石油化工企业稳高压消防给水系统设计 被引量:1

Design of Fire Water Supply System of Stable High Pressure in Petrochemical Enterprise
下载PDF
导出
摘要 针对稳高压消防给水系统的相关内容,进行了介绍,并对稳高压消防给水系统中消防水泵和稳压泵设计参数的确定、联锁控制方案的设计,进行了详细的论述。同时对稳高压消防给水系统中是否应设高位消防水箱、消防水泵接合器及消火栓处远程启动消防泵按钮进行了分析,提出了个人的见解。 Aiming at the relational contents of fire water supply system of stable high pressure were introduced,and the determination of design parameters of fire pump and pressure maintenance pump,design schemes of the interlock control were described in detail in fire water supply system of stable high pressure. At the same time,whether fire cistern of the most high position,fire pump adapter and long- distance button to start the fire pump by fire hydrant should be set in fire water supply system of stable high pressure,which was analyzed,and personal opinions were given.
作者 李洪
出处 《广州化工》 CAS 2015年第8期170-172,共3页 GuangZhou Chemical Industry
关键词 稳高压 消防给水系统 消防泵 化工 问题分析 stable high pressure fire water supply system fire pump chemical industry problem analysis
  • 相关文献

参考文献7

二级参考文献7

  • 1FM DS0307,Fire protection pumps(June 2009)[S].
  • 2NFPA 20,Standard for the installation of stationary pumpsfor fire protection(2003 Edition)[S].
  • 3GB50160-92(1999年版)石油化工企业设计防火规范.
  • 4.GB50160-92(1999年版)石油化工企业设计防火规范[S].中国计划出版社,1999..
  • 5.GBJ16-87(2001年版)建筑设计防火规范[S].中国计划出版社,2001..
  • 6.GB50045-95(2001年版)高层民用建筑设计防火规范[S].中国计划出版社,2001..
  • 7GB50016-2006《建筑设计防火规范》.

共引文献20

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部