针对稳高压消防给水系统的相关内容,进行了介绍,并对稳高压消防给水系统中消防水泵和稳压泵设计参数的确定、联锁控制方案的设计,进行了详细的论述。同时对稳高压消防给水系统中是否应设高位消防水箱、消防水泵接合器及消火栓处远程启动消防泵按钮进行了分析,提出了个人的见解。
Aiming at the relational contents of fire water supply system of stable high pressure were introduced,and the determination of design parameters of fire pump and pressure maintenance pump,design schemes of the interlock control were described in detail in fire water supply system of stable high pressure. At the same time,whether fire cistern of the most high position,fire pump adapter and long- distance button to start the fire pump by fire hydrant should be set in fire water supply system of stable high pressure,which was analyzed,and personal opinions were given.