摘要
武汉乙烯装置丙烯制冷压缩机K-501自开工以来一直超出设计负荷,通过对各种超负荷影响因素的分析,找出超负荷的原因,并根据分析的结果不断的优化调整,降低丙烯制冷压缩机的负荷,增强装置的操作弹性,并且减少蒸汽消耗量,达到节能降耗目的。
Since the plant was put into operation,the propylene refrigeration compressor K- 501 had continued working overload. Through analyzing a variety of reasons was found out. According to the result of the analysis,a series of measures were taken to reduce load,enhance the flexibility and cut down the consumption of vapor.
出处
《广州化工》
CAS
2015年第8期173-175,共3页
GuangZhou Chemical Industry
关键词
丙烯压缩机
超负荷
分析
propylene compressor
overload
analysis